Low sensitivity of malaria rapid diagnostic tests stored at room temperature in the Brazilian Amazon Region

Luciano Teixeira Gomes, Mauro Shugiro Tada, Tony Hiroshi Katsuragawa, Marinete Marins Póvoa, Giselle MR Viana, Maria das Graças Costa Alecrim, Frankllin S De Santana-Filho, Ana Ruth Lima Arcanjo, Alvaro A.R.A Couto, Vanja Suely Pachiano Calvosa, Andréia Ferreira Nery, Cor Jésus Fernandes Fontes

Open full text 12 citations

Abstract

INTRODUCTION: In remote areas of the Amazon Region, diagnosis of malaria by microscopy is practically impossible. This study aimed to evaluate the performance of two rapid diagnostic tests (RDTs) targeting different malaria antigens stored at room temperature in the Brazilian Amazon Region. METHODOLOGY: Performance of the OptiMal Pf/Pan test and ICT-Now Pf/Pan test was analyzed retrospectively in 1,627 and 1,602 blood samples, respectively. Tests were performed over a 15-month period. Kits were stored at room temperature in five community health centres located in the Brazilian Amazon Region. RDT results were compared with thick blood smear (TBS) results to determine sensitivity, specificity, and accuracy of the RDT. RESULTS: The sensitivities of the OptiMal Pf/Pan test were 79.7% for Plasmodium falciparum malaria diagnosis and 85.7% for non-P. falciparum infections. The results showed a crude agreement of 88.5% for P. falciparum, and 88.3% for non-P. falciparum infections (Kappa index = 0.74 and 0.75, respectively). For the ICT-Now Pf/Pan test (CI 95%), the sensitivities were 87.9% for P. falciparum malaria diagnosis and 72.5% for non-P. falciparum infection. Crude agreement between the ICT-Now Pf/Pan test and TBS was 91.4% for P. falciparum and 79.7% for non-P. falciparum infection. The Kappa index was 0.81 and 0.59 for the final diagnosis of P. falciparum and non-P. falciparum, respectively. Higher levels of parasitaemia were associated with higher crude agreement between RDT and TBS. CONCLUSIONS: The sensitivities of RDTs stored at room temperature over a 15-month period and performed in field conditions were lower than those previously reported.

Open-access reader

About this research paper

What this paper is about

INTRODUCTION: In remote areas of the Amazon Region, diagnosis of malaria by microscopy is practically impossible. This study aimed to evaluate the performance of two rapid diagnostic tests (RDTs) targeting different malaria antigens stored at room temperature in the Brazilian Amazon Region. METHODOLOGY: Performance of the OptiMal Pf/Pan test and ICT-Now Pf/Pan test was analyzed retrospectively in 1,627 and 1,602 blood samples, respectively. Tests were performed over a 15-month period. Kits were stored at room temperature in five community health centres located in the Brazilian Amazon Region. RDT results were compared with thick blood smear (TBS) results to determine sensitivity, specificity, and accuracy of the RDT. RESULTS: The sensitivities of the OptiMal Pf/Pan test were 79.7% for Plasmodium falciparum malaria diagnosis and 85.7% for non-P. falciparum infections. The results showed a crude agreement of 88.5% for P. falciparum, and 88.3% for non-P. falciparum infections (Kappa index = 0.74 and 0.75, respectively). For the ICT-Now Pf/Pan test (CI 95%), the sensitivities were 87.9% for P. falciparum malaria diagnosis and 72.5% for non-P. falciparum infection. Crude agreement between the ICT-Now Pf/Pan test and TBS was 91.4% for P. falciparum and 79.7% for non-P. falciparum infection. The Kappa index was 0.81 and 0.59 for the final diagnosis of P. falciparum and non-P. falciparum, respectively. Higher levels of parasitaemia were associated with higher crude agreement between RDT and TBS. CONCLUSIONS: The sensitivities of RDTs stored at room temperature over a 15-month period and performed in field conditions were lower than those previously reported.

Why it matters

OpenAlex reports 12 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

INTRODUCTION: In remote areas of the Amazon Region, diagnosis of malaria by microscopy is practically impossible. This study aimed to evaluate the performance of two rapid diagnostic tests (RDTs) targeting different malaria antigens stored at room temperature in the Brazilian Amazon Region. METHODOLOGY: Performance of the OptiMal Pf/Pan test and ICT-Now Pf/Pan test was analyzed retrospectively in 1,627 and 1,602 blood samples, respectively. Tests were performed over a 15-month period. Kits were stored at room temperature in five community health centres located in the Brazilian Amazon Region. RDT results were compared with thick blood smear (TBS) results to determine sensitivity, specificity, and accuracy of the RDT. RESULTS: The sensitivities of the OptiMal Pf/Pan test were 79.7% for Plasmodium falciparum malaria diagnosis and 85.7% for non-P. falciparum infections. The results showed a crude agreement of 88.5% for P. falciparum, and 88.3% for non-P. falciparum infections (Kappa index = 0.74 and 0.75, respectively). For the ICT-Now Pf/Pan test (CI 95%), the sensitivities were 87.9% for P. falciparum malaria diagnosis and 72.5% for non-P. falciparum infection. Crude agreement between the ICT-Now Pf/Pan test and TBS was 91.4% for P. falciparum and 79.7% for non-P. falciparum infection. The Kappa index was 0.81 and 0.59 for the final diagnosis of P. falciparum and non-P. falciparum, respectively. Higher levels of parasitaemia were associated with higher crude agreement between RDT and TBS. CONCLUSIONS: The sensitivities of RDTs stored at room temperature over a 15-month period and performed in field conditions were lower than those previously reported.

Key concepts: Malaria, Rapid diagnostic test, Plasmodium falciparum, Blood smear, Amazon rainforest, Medicine, Kappa, Diagnostic test