2013Journal of International Medical ResearchOpen access

Comparative evaluation of a novel TaqMan real-time reverse transcription–polymerase chain reaction assay for hepatitis A virus detection

Feng Qiu, Huihui Zheng, Yi Yao, Zhiyuan Jia, Jingyuan Cao, Shengli Bi

Open full text 5 citations

Abstract

OBJECTIVE: To develop and evaluate a novel system for detecting and quantifying hepatitis A virus (HAV) nucleic acid. METHODS: Real-time TaqMan® reverse transcription-polymerase chain reaction (PCR) procedures were established, based on amplification of the highly conserved 5'-non-coding region. Synthetic single-stranded RNA transcripts synthesized in vitro were used as the quantification standard. Ten-fold dilutions were prepared from HAV strain stock suspension to determine precision, accuracy, sensitivity and specificity. In addition, serum specimens from patients with acute HAV underwent clinical evaluation. RESULTS: The novel assay had a detection limit for HAV RNA of 10 TCID50/ml (where TCID50 is median tissue culture infective dose). It was more sensitive and specific than the commercial quantitative PCR kit manufactured by Shanghai Zhijiang Bio-Tech. However, the Artus HAV RT-PCR kit (Qiagen) had the best performance of the three assays and had a detection limit of 5 TCID50/ml. The new HAV real-time PCR detection system was also successfully applied in 90 serum specimens from patients with confirmed acute HAV infection. CONCLUSION: Considering its high reproducibility, sensitivity, specificity and simplicity, this novel amplification system may be suitable for wide clinical application as a diagnostic tool, and for the surveillance and investigation of infectious diseases in developing countries where HAV is endemic.

About this research paper

What this paper is about

OBJECTIVE: To develop and evaluate a novel system for detecting and quantifying hepatitis A virus (HAV) nucleic acid. METHODS: Real-time TaqMan® reverse transcription-polymerase chain reaction (PCR) procedures were established, based on amplification of the highly conserved 5'-non-coding region. Synthetic single-stranded RNA transcripts synthesized in vitro were used as the quantification standard. Ten-fold dilutions were prepared from HAV strain stock suspension to determine precision, accuracy, sensitivity and specificity. In addition, serum specimens from patients with acute HAV underwent clinical evaluation. RESULTS: The novel assay had a detection limit for HAV RNA of 10 TCID50/ml (where TCID50 is median tissue culture infective dose). It was more sensitive and specific than the commercial quantitative PCR kit manufactured by Shanghai Zhijiang Bio-Tech. However, the Artus HAV RT-PCR kit (Qiagen) had the best performance of the three assays and had a detection limit of 5 TCID50/ml. The new HAV real-time PCR detection system was also successfully applied in 90 serum specimens from patients with confirmed acute HAV infection. CONCLUSION: Considering its high reproducibility, sensitivity, specificity and simplicity, this novel amplification system may be suitable for wide clinical application as a diagnostic tool, and for the surveillance and investigation of infectious diseases in developing countries where HAV is endemic.

Why it matters

OpenAlex reports 5 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

OBJECTIVE: To develop and evaluate a novel system for detecting and quantifying hepatitis A virus (HAV) nucleic acid. METHODS: Real-time TaqMan® reverse transcription-polymerase chain reaction (PCR) procedures were established, based on amplification of the highly conserved 5'-non-coding region. Synthetic single-stranded RNA transcripts synthesized in vitro were used as the quantification standard. Ten-fold dilutions were prepared from HAV strain stock suspension to determine precision, accuracy, sensitivity and specificity. In addition, serum specimens from patients with acute HAV underwent clinical evaluation. RESULTS: The novel assay had a detection limit for HAV RNA of 10 TCID50/ml (where TCID50 is median tissue culture infective dose). It was more sensitive and specific than the commercial quantitative PCR kit manufactured by Shanghai Zhijiang Bio-Tech. However, the Artus HAV RT-PCR kit (Qiagen) had the best performance of the three assays and had a detection limit of 5 TCID50/ml. The new HAV real-time PCR detection system was also successfully applied in 90 serum specimens from patients with confirmed acute HAV infection. CONCLUSION: Considering its high reproducibility, sensitivity, specificity and simplicity, this novel amplification system may be suitable for wide clinical application as a diagnostic tool, and for the surveillance and investigation of infectious diseases in developing countries where HAV is endemic.

Key concepts: TaqMan, Virology, Reverse transcription polymerase chain reaction, Serial dilution, Medicine, Reverse transcriptase, Real-time polymerase chain reaction, Polymerase chain reaction

Related papers

Back to paper searchBrowse research topicsOriginal source