Influence of a Non-Ionic Radiography Contrast Medium on the Microcirculation
Ronald R. Bach, Friedrich Jung, Bruno Scheller, Björn Hummel, Cem Özbek, Stefan G. Spitzer, Hermann J. Schieffer
Abstract
Ronald R. Bach, Friedrich Jung, Bruno Scheller, Björn Hummel, Cem Özbek, Stefan G. Spitzer, Hermann J. Schieffer
Abstract
UNLABELLED: PURPOSE, MATERIAL AND METHODS: Microcirculatory disturbances may be responsible for some of the adverse effects induced by contrast media. The influence of iopromide 370 (Ultravist) on cutaneous microcirculation was therefore investigated in 15 patients in a prospective study. Twenty ml of iopromide and 20 ml 0.9% NaCl were injected as reference in the subclavian artery at the beginning of a diagnostic coronary angiography. Erythrocyte velocity was measured in ipsilateral nailfold capillaries at the beginning of, during, and after the injection continuously up to 6 min after injection. RESULTS: On average, 30 s after injection of contrast medium, erythrocyte velocity decreased significantly by 51.3% (p<0.0001) and remained reduced up to 120 s. This reaction was observed in 14 out of 15 patients. Three patients showed a temporary cessation of capillary blood flow. CONCLUSION: The adverse effects sometimes seen during coronary angiography can be explained if similar contrast medium induced microcirculatory disturbances in the myocardial vasculature.
OpenAlex reports 39 citations for this work. Citation counts describe recorded attention and do not establish research quality.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
UNLABELLED: PURPOSE, MATERIAL AND METHODS: Microcirculatory disturbances may be responsible for some of the adverse effects induced by contrast media. The influence of iopromide 370 (Ultravist) on cutaneous microcirculation was therefore investigated in 15 patients in a prospective study. Twenty ml of iopromide and 20 ml 0.9% NaCl were injected as reference in the subclavian artery at the beginning of a diagnostic coronary angiography. Erythrocyte velocity was measured in ipsilateral nailfold capillaries at the beginning of, during, and after the injection continuously up to 6 min after injection. RESULTS: On average, 30 s after injection of contrast medium, erythrocyte velocity decreased significantly by 51.3% (p<0.0001) and remained reduced up to 120 s. This reaction was observed in 14 out of 15 patients. Three patients showed a temporary cessation of capillary blood flow. CONCLUSION: The adverse effects sometimes seen during coronary angiography can be explained if similar contrast medium induced microcirculatory disturbances in the myocardial vasculature.
Key concepts: Iopromide, Medicine, Contrast medium, Microcirculation, Angiography, Iohexol, Radiology, Contrast (vision)