2009Eurasian Journal of Analytical ChemistryOpen access

Simultaneous Estimation of Ciprofloxacin Hydrochloride, Ofloxacin, Tinidazole and Ornidazole by Reverse Phase – High Performance Liquid Chromatography

Ranjit Singh, Mukesh Maithani, Shailendra K. Saraf, Shubhini A. Saraf, C. Ram

Open full text 25 citations

Abstract

A new, simple, rapid, selective, precise and accurate isocratic reverse phase high performance liquid chromatography assay has been developed for simultaneous estimation of Ciprofloxacin Hydrochloride, Ofloxacin, Tinidazole and Ornidazole in tablet formulations. The separation was achieved by using C-18 column (Phenomenax, 250 x 4.6mm i.d.) coupled with a guard column of same material, in mobile phase Acetonitrile: Water: Tri ethylamine (25:75). The pH of mobile phase was adjusted to 6.0 ± 0.1 with 50% ortho phosphoric acid. The flow rate was 1.0 mL.min -1 and the separated drugs were detected using UV detector at the wavelength of 300 nm. The retention time of Ciprofloxacin Hydrochloride, Ofloxacin, Tinidazole, and Ornidazole was noted to be 2.7, 3.5, 4.5 and 5.8 min, respectively, indicative of rather shorter analysis time. The method was validated as per ICH guidelines. The proposed method was found to be accurate, reproducible, and consistent. It was successfully applied for the analysis of these drugs in marketed formulations and could be effectively used for the routine analysis of formulations containing any one of the above drugs, or a combination, without any alteration in the chromatographic conditions.

About this research paper

What this paper is about

A new, simple, rapid, selective, precise and accurate isocratic reverse phase high performance liquid chromatography assay has been developed for simultaneous estimation of Ciprofloxacin Hydrochloride, Ofloxacin, Tinidazole and Ornidazole in tablet formulations. The separation was achieved by using C-18 column (Phenomenax, 250 x 4.6mm i.d.) coupled with a guard column of same material, in mobile phase Acetonitrile: Water: Tri ethylamine (25:75). The pH of mobile phase was adjusted to 6.0 ± 0.1 with 50% ortho phosphoric acid. The flow rate was 1.0 mL.min -1 and the separated drugs were detected using UV detector at the wavelength of 300 nm. The retention time of Ciprofloxacin Hydrochloride, Ofloxacin, Tinidazole, and Ornidazole was noted to be 2.7, 3.5, 4.5 and 5.8 min, respectively, indicative of rather shorter analysis time. The method was validated as per ICH guidelines. The proposed method was found to be accurate, reproducible, and consistent. It was successfully applied for the analysis of these drugs in marketed formulations and could be effectively used for the routine analysis of formulations containing any one of the above drugs, or a combination, without any alteration in the chromatographic conditions.

Why it matters

OpenAlex reports 25 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

A new, simple, rapid, selective, precise and accurate isocratic reverse phase high performance liquid chromatography assay has been developed for simultaneous estimation of Ciprofloxacin Hydrochloride, Ofloxacin, Tinidazole and Ornidazole in tablet formulations. The separation was achieved by using C-18 column (Phenomenax, 250 x 4.6mm i.d.) coupled with a guard column of same material, in mobile phase Acetonitrile: Water: Tri ethylamine (25:75). The pH of mobile phase was adjusted to 6.0 ± 0.1 with 50% ortho phosphoric acid. The flow rate was 1.0 mL.min -1 and the separated drugs were detected using UV detector at the wavelength of 300 nm. The retention time of Ciprofloxacin Hydrochloride, Ofloxacin, Tinidazole, and Ornidazole was noted to be 2.7, 3.5, 4.5 and 5.8 min, respectively, indicative of rather shorter analysis time. The method was validated as per ICH guidelines. The proposed method was found to be accurate, reproducible, and consistent. It was successfully applied for the analysis of these drugs in marketed formulations and could be effectively used for the routine analysis of formulations containing any one of the above drugs, or a combination, without any alteration in the chromatographic conditions.

Key concepts: Ornidazole, Chromatography, Tinidazole, Ofloxacin, Chemistry, Ciprofloxacin Hydrochloride, High-performance liquid chromatography, Phosphoric acid

Related papers

Back to paper searchBrowse research topicsOriginal source
Simultaneous Estimation of Ciprofloxacin Hydrochloride, Ofloxacin, Tinidazole and Ornidazole by Reverse Phase – High Performance Liquid Chromatography — Research Paper | ScholarLens