Evaluation of urinalysis parameters to predict urinary-tract infection
Juliana Conrad dos Santos, Liliana Portal Weber, Leandro Reus Rodrigues Perez
Abstract
Open-access reader
Juliana Conrad dos Santos, Liliana Portal Weber, Leandro Reus Rodrigues Perez
Abstract
Open-access reader
We evaluated the performance of automated-flow cytometry, urinalysis dipsticks and microscopic urine sediment analysis as predictors of urinary tract infection. Urine cultures were used as a reference method for comparison. Six-hundred-seventy-five urine samples from hospitalized and not hospitalized patients attended at Hospital Mãe de Deus, Porto Alegre, in south Brazil, were included in the study. Among the individual measures analyzed, intense bacteriuria in the microscopic analysis of urinary sediment gave an accuracy of 92.9%. A combination between intense bacteriuria (microscopic analysis) and >20 leukocytes per microL of urine (flow cytometry) gave a higher accuracy (97.3%). We conclude that though it is laborious, microscopic urinalysis is a good analytical tool. Taken together with flow cytometry and dipsticks, we obtained a clinically-acceptable prediction of urinary-tract infection.
OpenAlex reports 48 citations for this work. Citation counts describe recorded attention and do not establish research quality.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
We evaluated the performance of automated-flow cytometry, urinalysis dipsticks and microscopic urine sediment analysis as predictors of urinary tract infection. Urine cultures were used as a reference method for comparison. Six-hundred-seventy-five urine samples from hospitalized and not hospitalized patients attended at Hospital Mãe de Deus, Porto Alegre, in south Brazil, were included in the study. Among the individual measures analyzed, intense bacteriuria in the microscopic analysis of urinary sediment gave an accuracy of 92.9%. A combination between intense bacteriuria (microscopic analysis) and >20 leukocytes per microL of urine (flow cytometry) gave a higher accuracy (97.3%). We conclude that though it is laborious, microscopic urinalysis is a good analytical tool. Taken together with flow cytometry and dipsticks, we obtained a clinically-acceptable prediction of urinary-tract infection.
Key concepts: Urinalysis, Urine, Bacteriuria, Urinary system, Medicine, Flow cytometry, Urology, Urinary sediment