2011Diabetes Technology & TherapeuticsOpen access

One in Five Laboratories Using Various Hemoglobin A 1c Methods Do Not Meet the Criteria for Optimal Diabetes Care Management

Erna Lenters‐Westra, Cas Weykamp, Roger K. Schindhelm, Carla Siebelder, Henk J.G. Bilo, Robbert J. Slingerland

Open full text 22 citations

Abstract

BACKGROUND: We assessed the reference change value (RCV) of currently available hemoglobin A(1c) (HbA(1c)) laboratory assays, which is defined as the critical difference between two consecutive HbA(1c) measurements representing a significant change in health status. METHODS: We examined the individual laboratory coefficients of variation (CVs) in the Dutch/Belgian quality scheme based on 24 lyophilized samples and calculated the RCV per laboratory (n = 220) and per assay method. In addition, two pooled whole blood samples were sent to the participating laboratories. The individual laboratory results were compared to the assigned value ± an allowable total error (TE(a)) of 6%. RESULTS: At HbA(1c) values of 41.0 mmol/mol (5.9%-Diabetes Control and Complications Trial [DCCT]) and 61.8 mmol/mol (7.8%-DCCT), 99% and 98%, respectively, of the laboratories reported a value within a TE(a) limit of 6%. The analytical CV of the HbA(1c) method used in 78% of the laboratories is <2.4%. The mean RCV at an HbA(1c) value of 53 mmol/mol (7.0%-DCCT) for methods of Bio-Rad is 5.9 mmol/mol (0.59%-DCCT); for Arkray/Menarini, 4.3 mmol/mol (0.43%-DCCT); for Roche, 6.5 mmol/mol (0.65%-DCCT); for Tosoh, 3.3 mmol/mol (0.33%-DCCT); and for other methods, 6.3 mmol/mol (0.63%-DCCT). CONCLUSIONS: The analytical performance of the majority of laboratory HbA(1c) methods is within the clinical requirements. However, based on the calculated RCV, 21.8% of the laboratories using different HbA(1c) methods are not able to distinguish an HbA(1c) result of 59 mmol/mol (7.5%-DCCT) from a previous HbA(1c) result of 53 mmol/mol (7.0%-DCCT). It can be presumed that differences in HbA(1c) results of 5 mmol/mol (0.5%-DCCT) do influence treatment decisions.

About this research paper

What this paper is about

BACKGROUND: We assessed the reference change value (RCV) of currently available hemoglobin A(1c) (HbA(1c)) laboratory assays, which is defined as the critical difference between two consecutive HbA(1c) measurements representing a significant change in health status. METHODS: We examined the individual laboratory coefficients of variation (CVs) in the Dutch/Belgian quality scheme based on 24 lyophilized samples and calculated the RCV per laboratory (n = 220) and per assay method. In addition, two pooled whole blood samples were sent to the participating laboratories. The individual laboratory results were compared to the assigned value ± an allowable total error (TE(a)) of 6%. RESULTS: At HbA(1c) values of 41.0 mmol/mol (5.9%-Diabetes Control and Complications Trial [DCCT]) and 61.8 mmol/mol (7.8%-DCCT), 99% and 98%, respectively, of the laboratories reported a value within a TE(a) limit of 6%. The analytical CV of the HbA(1c) method used in 78% of the laboratories is <2.4%. The mean RCV at an HbA(1c) value of 53 mmol/mol (7.0%-DCCT) for methods of Bio-Rad is 5.9 mmol/mol (0.59%-DCCT); for Arkray/Menarini, 4.3 mmol/mol (0.43%-DCCT); for Roche, 6.5 mmol/mol (0.65%-DCCT); for Tosoh, 3.3 mmol/mol (0.33%-DCCT); and for other methods, 6.3 mmol/mol (0.63%-DCCT). CONCLUSIONS: The analytical performance of the majority of laboratory HbA(1c) methods is within the clinical requirements. However, based on the calculated RCV, 21.8% of the laboratories using different HbA(1c) methods are not able to distinguish an HbA(1c) result of 59 mmol/mol (7.5%-DCCT) from a previous HbA(1c) result of 53 mmol/mol (7.0%-DCCT). It can be presumed that differences in HbA(1c) results of 5 mmol/mol (0.5%-DCCT) do influence treatment decisions.

Why it matters

OpenAlex reports 22 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

BACKGROUND: We assessed the reference change value (RCV) of currently available hemoglobin A(1c) (HbA(1c)) laboratory assays, which is defined as the critical difference between two consecutive HbA(1c) measurements representing a significant change in health status. METHODS: We examined the individual laboratory coefficients of variation (CVs) in the Dutch/Belgian quality scheme based on 24 lyophilized samples and calculated the RCV per laboratory (n = 220) and per assay method. In addition, two pooled whole blood samples were sent to the participating laboratories. The individual laboratory results were compared to the assigned value ± an allowable total error (TE(a)) of 6%. RESULTS: At HbA(1c) values of 41.0 mmol/mol (5.9%-Diabetes Control and Complications Trial [DCCT]) and 61.8 mmol/mol (7.8%-DCCT), 99% and 98%, respectively, of the laboratories reported a value within a TE(a) limit of 6%. The analytical CV of the HbA(1c) method used in 78% of the laboratories is <2.4%. The mean RCV at an HbA(1c) value of 53 mmol/mol (7.0%-DCCT) for methods of Bio-Rad is 5.9 mmol/mol (0.59%-DCCT); for Arkray/Menarini, 4.3 mmol/mol (0.43%-DCCT); for Roche, 6.5 mmol/mol (0.65%-DCCT); for Tosoh, 3.3 mmol/mol (0.33%-DCCT); and for other methods, 6.3 mmol/mol (0.63%-DCCT). CONCLUSIONS: The analytical performance of the majority of laboratory HbA(1c) methods is within the clinical requirements. However, based on the calculated RCV, 21.8% of the laboratories using different HbA(1c) methods are not able to distinguish an HbA(1c) result of 59 mmol/mol (7.5%-DCCT) from a previous HbA(1c) result of 53 mmol/mol (7.0%-DCCT). It can be presumed that differences in HbA(1c) results of 5 mmol/mol (0.5%-DCCT) do influence treatment decisions.

Key concepts: Medicine, Diabetes mellitus, Hemoglobin, Hemoglobin A, Internal medicine, Nuclear medicine, Surgery, Endocrinology

Related papers

Back to paper searchBrowse research topicsOriginal source
One in Five Laboratories Using Various Hemoglobin A 1c Methods Do Not Meet the Criteria for Optimal Diabetes Care Management — Research Paper | ScholarLens