Statistics and Analysis of Lightning Flashovers of Transmission Lines during 2000~2007

Xiaolan Li, Chen Jiahong, Shanqiang Gu, Xuefang Tong

Open publisher page 20 citations

Abstract

In order to analyze the correlativity between the lightning flashover amount and the time factors, about 425 times lightning flashover on 187 lines in 10 power supply companies of 220 kV and 500 kV transmission lines during 2000~2007 are investigated in this paper. The correlativity between the lightning flashover amount and the time factors is analyzed. According to the lightning stroke accidents investigation records, the lightning flashover amount of transmission line increases from the year of 2000 to 2007. In each year lightning flashovers mostly happen in the month of June, July and August. Similarly in each day the flashover amount also varies with the time of day obviously. These lightning flashovers mainly occur during 14:00~21:00 in the afternoon. The analysis results in this paper have a good agreement with the meteorological observations. And these results provide good reference for the lightning protection work in power system.

About this research paper

What this paper is about

In order to analyze the correlativity between the lightning flashover amount and the time factors, about 425 times lightning flashover on 187 lines in 10 power supply companies of 220 kV and 500 kV transmission lines during 2000~2007 are investigated in this paper. The correlativity between the lightning flashover amount and the time factors is analyzed. According to the lightning stroke accidents investigation records, the lightning flashover amount of transmission line increases from the year of 2000 to 2007. In each year lightning flashovers mostly happen in the month of June, July and August. Similarly in each day the flashover amount also varies with the time of day obviously. These lightning flashovers mainly occur during 14:00~21:00 in the afternoon. The analysis results in this paper have a good agreement with the meteorological observations. And these results provide good reference for the lightning protection work in power system.

Why it matters

OpenAlex reports 20 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

In order to analyze the correlativity between the lightning flashover amount and the time factors, about 425 times lightning flashover on 187 lines in 10 power supply companies of 220 kV and 500 kV transmission lines during 2000~2007 are investigated in this paper. The correlativity between the lightning flashover amount and the time factors is analyzed. According to the lightning stroke accidents investigation records, the lightning flashover amount of transmission line increases from the year of 2000 to 2007. In each year lightning flashovers mostly happen in the month of June, July and August. Similarly in each day the flashover amount also varies with the time of day obviously. These lightning flashovers mainly occur during 14:00~21:00 in the afternoon. The analysis results in this paper have a good agreement with the meteorological observations. And these results provide good reference for the lightning protection work in power system.