An evaluation of the shielding effectiveness of lead aprons used in clinics for protection against ionising radiation from novel radioisotopes
Pradip Deb, Robert N. Jamison, Lisa Mong, U Paul
Abstract
Pradip Deb, Robert N. Jamison, Lisa Mong, U Paul
Abstract
The purpose of this study is to evaluate the effectiveness of personal radiation shields currently worn in hospital and other diagnostic environments. This study was performed with four different radioisotopes; (18)F, (99m)Tc, (124)I and (131)I. (18)F results showed a decrease in dose with 0.5-mm Pb shielding but the reduction provided does not warrant its use clinically. (124)I testing demonstrated that dose enhancement can occur in greater shield thicknesses. PET isotope (124)I can be adequately shielded using 0.25-mm Pb equivalent aprons but any higher thickness increase the wearer's dose. As a result more shielding does not always equal more protection. The (131)I test showed that no dose reduction occurred, even when tested with up to 1.25-mm Pb equivalent shielding. Novel radioisotopes being used in the laboratory and clinic should be individually tested as each requires specific shielding testing.
OpenAlex reports 15 citations for this work. Citation counts describe recorded attention and do not establish research quality.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
The purpose of this study is to evaluate the effectiveness of personal radiation shields currently worn in hospital and other diagnostic environments. This study was performed with four different radioisotopes; (18)F, (99m)Tc, (124)I and (131)I. (18)F results showed a decrease in dose with 0.5-mm Pb shielding but the reduction provided does not warrant its use clinically. (124)I testing demonstrated that dose enhancement can occur in greater shield thicknesses. PET isotope (124)I can be adequately shielded using 0.25-mm Pb equivalent aprons but any higher thickness increase the wearer's dose. As a result more shielding does not always equal more protection. The (131)I test showed that no dose reduction occurred, even when tested with up to 1.25-mm Pb equivalent shielding. Novel radioisotopes being used in the laboratory and clinic should be individually tested as each requires specific shielding testing.
Key concepts: Electromagnetic shielding, Lead apron, Radiation protection, Equivalent dose, Shields, Ionizing radiation, Nuclear medicine, Shielded cable