200711th International Conference on Environmental Remediation and Radioactive Waste Management, Parts A and BRequires access

Using Pressure Decay Methodology to Detect Glovebox Glove Failures

Michael E. Cournoyer, Stephen Schreiber, Steve D. Chunglo

Open publisher page 3 citations

Abstract

At the Los Alamos National Laboratory Plutonium’s Facility (TA-55), various isotopes of plutonium along with other actinides are handled in a glove box environment. Data collected from 700 unplanned openings in the glovebox environment indicate that 40% of these ruptures are glove failures, openings in the glove caused by degradation of the mechanical properties over time, e.g. exposure to chemicals and nuclear materials. The primary means of minimizing these types of glove failures is through a robust glove inspection program. Through a collaborative effort with Getinge La Calhe`ne, we have beta-tested their In-situ Glove Leak Tester (GLT2) in an active ventilation glovebox environment. This instrument tests glovebox gloves in place and uses pressure decay methodology, to tests up to four gloves at a time, in less than 5 minutes per test, and provides documentation of each test. While the GLT2 has been successful in static pressure enclosures that are possible in the pharmaceutical industry, the uninterruptible active negative pressure gloveboxes used in the nuclear industry present a new set of issues. In the following report, these issues are addressed and the limits of this technology defined, with the end result being that waste generated from glove failures has been minimized.

About this research paper

What this paper is about

At the Los Alamos National Laboratory Plutonium’s Facility (TA-55), various isotopes of plutonium along with other actinides are handled in a glove box environment. Data collected from 700 unplanned openings in the glovebox environment indicate that 40% of these ruptures are glove failures, openings in the glove caused by degradation of the mechanical properties over time, e.g. exposure to chemicals and nuclear materials. The primary means of minimizing these types of glove failures is through a robust glove inspection program. Through a collaborative effort with Getinge La Calhe`ne, we have beta-tested their In-situ Glove Leak Tester (GLT2) in an active ventilation glovebox environment. This instrument tests glovebox gloves in place and uses pressure decay methodology, to tests up to four gloves at a time, in less than 5 minutes per test, and provides documentation of each test. While the GLT2 has been successful in static pressure enclosures that are possible in the pharmaceutical industry, the uninterruptible active negative pressure gloveboxes used in the nuclear industry present a new set of issues. In the following report, these issues are addressed and the limits of this technology defined, with the end result being that waste generated from glove failures has been minimized.

Why it matters

OpenAlex reports 3 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

At the Los Alamos National Laboratory Plutonium’s Facility (TA-55), various isotopes of plutonium along with other actinides are handled in a glove box environment. Data collected from 700 unplanned openings in the glovebox environment indicate that 40% of these ruptures are glove failures, openings in the glove caused by degradation of the mechanical properties over time, e.g. exposure to chemicals and nuclear materials. The primary means of minimizing these types of glove failures is through a robust glove inspection program. Through a collaborative effort with Getinge La Calhe`ne, we have beta-tested their In-situ Glove Leak Tester (GLT2) in an active ventilation glovebox environment. This instrument tests glovebox gloves in place and uses pressure decay methodology, to tests up to four gloves at a time, in less than 5 minutes per test, and provides documentation of each test. While the GLT2 has been successful in static pressure enclosures that are possible in the pharmaceutical industry, the uninterruptible active negative pressure gloveboxes used in the nuclear industry present a new set of issues. In the following report, these issues are addressed and the limits of this technology defined, with the end result being that waste generated from glove failures has been minimized.

Key concepts: Glovebox, Plutonium, Environmental science, Waste management, Engineering, Nuclear engineering, Mechanical engineering, Radiochemistry

Related papers

Back to paper searchBrowse research topicsOriginal source
Using Pressure Decay Methodology to Detect Glovebox Glove Failures — Research Paper | ScholarLens