Determination of Serum Testosterone Levels with Liquid Chromatography-Isotope Dilution Tandem Mass Spectrometry and Comparision with Other Immunoassays
Celik HT, Serdar MA
Abstract
Open-access reader
Celik HT, Serdar MA
Abstract
Open-access reader
Background: In clinical laboratories, Determination of serum testosterone levels in routine is challenging.Reliable analysis of bioavailable testosterone is difficult.Methods: After liquid-liquid extraction, Shimadzu Prominence LC unit coupled to API 3200 mass spectrometer with atmospheric pressure chemical ionisation was used to quantify serum testosterone levels.Serum testosterone results taken from tandem mass spectrometry were compared with Roche, Beckman and Abbott commercial automated testosterone immunoassaysResults: In LC-MS/MS method, linearity for testosterone was 0.005-15.915ng/mL.Recovery was 97-108% for 0.06-16 ng/mL concentration range.Intraday and inter-day CVs were 6.3,9,7; 2,2,8.7 and 1.3,0.3 for low (0.969 ng/ mL), intermediate (4.816 ng/mL) and high (8.084ng/mL) testosterone concentrations, respectively.There was a good correlation between commercial immunoassays.In method comparision, agreement was closest with Roche and LC-MS/MS method (r=0.9670).Discussion: In contrast to commercial testosterone immunoassays, LC-MS/MS method is a reliable, simple and useful method for clinical laboratory practices.
OpenAlex reports 4 citations for this work. Citation counts describe recorded attention and do not establish research quality.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
Background: In clinical laboratories, Determination of serum testosterone levels in routine is challenging.Reliable analysis of bioavailable testosterone is difficult.Methods: After liquid-liquid extraction, Shimadzu Prominence LC unit coupled to API 3200 mass spectrometer with atmospheric pressure chemical ionisation was used to quantify serum testosterone levels.Serum testosterone results taken from tandem mass spectrometry were compared with Roche, Beckman and Abbott commercial automated testosterone immunoassaysResults: In LC-MS/MS method, linearity for testosterone was 0.005-15.915ng/mL.Recovery was 97-108% for 0.06-16 ng/mL concentration range.Intraday and inter-day CVs were 6.3,9,7; 2,2,8.7 and 1.3,0.3 for low (0.969 ng/ mL), intermediate (4.816 ng/mL) and high (8.084ng/mL) testosterone concentrations, respectively.There was a good correlation between commercial immunoassays.In method comparision, agreement was closest with Roche and LC-MS/MS method (r=0.9670).Discussion: In contrast to commercial testosterone immunoassays, LC-MS/MS method is a reliable, simple and useful method for clinical laboratory practices.
Key concepts: Isotope dilution, Chromatography, Liquid chromatography–mass spectrometry, Chemistry, Tandem mass spectrometry, Mass spectrometry, Testosterone (patch), Medicine