2011•Unpublished venueRequires access

Design of low power low noise amplifier for portable electrocardiogram recording system applications

Xiao Yang, Cheng Qi, Li-fei Lin, Weiwei Huang, Chaodong Ling

Open publisher page 14 citations

Abstract

Electrocardiogram (ECG) signals have the characteristics of low amplitude and low frequency. A low-power, low-noise and low voltage amplifier is required for long term ECG signals monitoring. Chopping technique is an efficient approach to decrease the 1/f noise of CMOS amplifiers, but conventional chopper amplifier consumes large power because it required a wide-band amplifier exceed chopping frequency and a post low-pass filter to filter modulation noise. Moreover, the DC offset created by skin-electrode interface can reach as high as ±100mV and can easily saturate the amplifier, which limits the amount of gain applied to amplifiers. In this paper, an amplifier with low power, low noise and electrode dc offset suppression is presented for ECG recording system applications. The main amplifier is a chopper amplifier without post low-pass filter, which can reduce power consumption. The complete amplifier configured with the low power chopper amplifier can suppress the electrode dc offset effectively. The circuit of the presented amplifier is designed in TSMC 0.18μm 1P4M CMOS process. The achieved input integrated referred noise voltage is 0.68μV rms from 0.1Hz to 150Hz with high CMRR of 107dB. The power consumption is 46.8 μW with μ0.9V supply.

About this research paper

What this paper is about

Electrocardiogram (ECG) signals have the characteristics of low amplitude and low frequency. A low-power, low-noise and low voltage amplifier is required for long term ECG signals monitoring. Chopping technique is an efficient approach to decrease the 1/f noise of CMOS amplifiers, but conventional chopper amplifier consumes large power because it required a wide-band amplifier exceed chopping frequency and a post low-pass filter to filter modulation noise. Moreover, the DC offset created by skin-electrode interface can reach as high as ±100mV and can easily saturate the amplifier, which limits the amount of gain applied to amplifiers. In this paper, an amplifier with low power, low noise and electrode dc offset suppression is presented for ECG recording system applications. The main amplifier is a chopper amplifier without post low-pass filter, which can reduce power consumption. The complete amplifier configured with the low power chopper amplifier can suppress the electrode dc offset effectively. The circuit of the presented amplifier is designed in TSMC 0.18μm 1P4M CMOS process. The achieved input integrated referred noise voltage is 0.68μV rms from 0.1Hz to 150Hz with high CMRR of 107dB. The power consumption is 46.8 μW with μ0.9V supply.

Why it matters

OpenAlex reports 14 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Electrocardiogram (ECG) signals have the characteristics of low amplitude and low frequency. A low-power, low-noise and low voltage amplifier is required for long term ECG signals monitoring. Chopping technique is an efficient approach to decrease the 1/f noise of CMOS amplifiers, but conventional chopper amplifier consumes large power because it required a wide-band amplifier exceed chopping frequency and a post low-pass filter to filter modulation noise. Moreover, the DC offset created by skin-electrode interface can reach as high as ±100mV and can easily saturate the amplifier, which limits the amount of gain applied to amplifiers. In this paper, an amplifier with low power, low noise and electrode dc offset suppression is presented for ECG recording system applications. The main amplifier is a chopper amplifier without post low-pass filter, which can reduce power consumption. The complete amplifier configured with the low power chopper amplifier can suppress the electrode dc offset effectively. The circuit of the presented amplifier is designed in TSMC 0.18μm 1P4M CMOS process. The achieved input integrated referred noise voltage is 0.68μV rms from 0.1Hz to 150Hz with high CMRR of 107dB. The power consumption is 46.8 μW with μ0.9V supply.

Key concepts: Amplifier, Electrical engineering, Computer science, Noise (video), Low-noise amplifier, Electronic engineering, Acoustics, Engineering

Related papers

Back to paper searchBrowse research topicsOriginal source
Design of low power low noise amplifier for portable electrocardiogram recording system applications — Research Paper | ScholarLens