1996Transportation Research Record Journal of the Transportation Research BoardRequires access

Capacity for North Carolina Freeway Work Zones

Karen K. Dixon, Joseph E. Hummer, A R Lorscheider

Open publisher page 85 citations

Abstract

Work zone capacity values for rural and urban freeways without continuous frontage roads were defined and determined. Data were collected using Nu-Metrics counters and classifiers at 24 work zones in North Carolina. The research included analysis of speed-flow behavior, evaluation of work zone sites based on lane configuration and site location, and determination of the location within the work zone where capacity is lowest. It was shown that the intensity of work activity and the type of study site (rural or urban) strongly affected work zone capacity. The data suggested that the location where capacity is reached is also variable based on the intensity of work. For heavy work in a two-lane to one-lane work zone configuration, the capacity values proposed at the active work area are approximately 1,200 vehicles per hour per lane for rural sites and 1,500 vehicles per hour per lane for urban sites. It is recommended that two distinct volumes be used when queue behavior in a freeway work zone is analyzed. The collapse from uninterrupted flow (designated work zone capacity) and the lower queue-discharge volume both should be considered.

About this research paper

What this paper is about

Work zone capacity values for rural and urban freeways without continuous frontage roads were defined and determined. Data were collected using Nu-Metrics counters and classifiers at 24 work zones in North Carolina. The research included analysis of speed-flow behavior, evaluation of work zone sites based on lane configuration and site location, and determination of the location within the work zone where capacity is lowest. It was shown that the intensity of work activity and the type of study site (rural or urban) strongly affected work zone capacity. The data suggested that the location where capacity is reached is also variable based on the intensity of work. For heavy work in a two-lane to one-lane work zone configuration, the capacity values proposed at the active work area are approximately 1,200 vehicles per hour per lane for rural sites and 1,500 vehicles per hour per lane for urban sites. It is recommended that two distinct volumes be used when queue behavior in a freeway work zone is analyzed. The collapse from uninterrupted flow (designated work zone capacity) and the lower queue-discharge volume both should be considered.

Why it matters

OpenAlex reports 85 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Work zone capacity values for rural and urban freeways without continuous frontage roads were defined and determined. Data were collected using Nu-Metrics counters and classifiers at 24 work zones in North Carolina. The research included analysis of speed-flow behavior, evaluation of work zone sites based on lane configuration and site location, and determination of the location within the work zone where capacity is lowest. It was shown that the intensity of work activity and the type of study site (rural or urban) strongly affected work zone capacity. The data suggested that the location where capacity is reached is also variable based on the intensity of work. For heavy work in a two-lane to one-lane work zone configuration, the capacity values proposed at the active work area are approximately 1,200 vehicles per hour per lane for rural sites and 1,500 vehicles per hour per lane for urban sites. It is recommended that two distinct volumes be used when queue behavior in a freeway work zone is analyzed. The collapse from uninterrupted flow (designated work zone capacity) and the lower queue-discharge volume both should be considered.

Key concepts: Work (physics), Work zone, Queue, Environmental science, Volume (thermodynamics), Traffic intensity, Intensity (physics), Traffic flow (computer networking)

Related papers

Back to paper searchBrowse research topicsOriginal source
Capacity for North Carolina Freeway Work Zones — Research Paper | ScholarLens