Effect of transient model of arrester on transient recovery voltage

Behrooz Vahidi, E. Goodarzi, Seyed Hossein Hosseinian, Masoumeh Tavakoli

Open publisher page 1 citations

Abstract

Circuit breakers can fail to interrupt fault current when the power system has transient recovery voltage (TRV) characteristics that exceed the rating of circuit breaker. TRV is the voltage across the opening contacts of a fault interrupting circuit breaker immediately after the arc is extinguished. The actual shape of the transient is determined by the connected lumped and distributed inductive and capacitive parameters defined by the bus equipment connected. Most of researcher has worked on TRV but not so much work is done on Rate of Rise of Recovery Voltage (RRRV). In the present paper fast transient model of arrester is used to simulate and analyze the TRV and RRRV by using MATLAB-SIMULINK software. The results of this simulation show the benefit of fast transient model of arrester for this kind of study.

About this research paper

What this paper is about

Circuit breakers can fail to interrupt fault current when the power system has transient recovery voltage (TRV) characteristics that exceed the rating of circuit breaker. TRV is the voltage across the opening contacts of a fault interrupting circuit breaker immediately after the arc is extinguished. The actual shape of the transient is determined by the connected lumped and distributed inductive and capacitive parameters defined by the bus equipment connected. Most of researcher has worked on TRV but not so much work is done on Rate of Rise of Recovery Voltage (RRRV). In the present paper fast transient model of arrester is used to simulate and analyze the TRV and RRRV by using MATLAB-SIMULINK software. The results of this simulation show the benefit of fast transient model of arrester for this kind of study.

Why it matters

OpenAlex reports 1 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Circuit breakers can fail to interrupt fault current when the power system has transient recovery voltage (TRV) characteristics that exceed the rating of circuit breaker. TRV is the voltage across the opening contacts of a fault interrupting circuit breaker immediately after the arc is extinguished. The actual shape of the transient is determined by the connected lumped and distributed inductive and capacitive parameters defined by the bus equipment connected. Most of researcher has worked on TRV but not so much work is done on Rate of Rise of Recovery Voltage (RRRV). In the present paper fast transient model of arrester is used to simulate and analyze the TRV and RRRV by using MATLAB-SIMULINK software. The results of this simulation show the benefit of fast transient model of arrester for this kind of study.

Key concepts: Transient recovery voltage, Circuit breaker, Transient (computer programming), Lightning arrester, Interrupt, Electrical engineering, Overvoltage, Fault (geology)

Related papers

Back to paper searchBrowse research topicsOriginal source
Effect of transient model of arrester on transient recovery voltage — Research Paper | ScholarLens