An Experimental Comparison of two Solar Photovoltaic- Thermal (PVT) Energy Conversion Systems for Production of Heat and Power
David Redpath, Harjit Singh, Christopher Tierney, Philip Dalzell
Abstract
David Redpath, Harjit Singh, Christopher Tierney, Philip Dalzell
Abstract
Two solar photovoltaic-thermal (PVT) energy conversion systems are described and their performance tested under laboratory conditions. One of these was a simple Flat Plate (FP-PVT) design, with headers and risers for heat removal the other a fixed linear axis Compound Parabolic Concentrating solar PVT (CPC-PVT) energy conversion system with a heat-pipe for removal of solar gain. Both had a low iron glass cover for high transmissivity of solar radiation, and polycrystalline silicon solar photovoltaic cells adhered to the absorber. Heat loss coefficient for the FP-PVT collector was measured as 4.1W/m2/K and 3.5W/m2/K for the CPC-PVT solar collector. These solar collectors were tested under steady state conditions using the solar simulator facility at the University of Ulster’s Centre for Sustainable Technologies. The FP-PVT and the CPC-PVT had a combined efficiency of 66.8% and 53.4% respectively producing both heat and power.
OpenAlex reports 15 citations for this work. Citation counts describe recorded attention and do not establish research quality.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
Two solar photovoltaic-thermal (PVT) energy conversion systems are described and their performance tested under laboratory conditions. One of these was a simple Flat Plate (FP-PVT) design, with headers and risers for heat removal the other a fixed linear axis Compound Parabolic Concentrating solar PVT (CPC-PVT) energy conversion system with a heat-pipe for removal of solar gain. Both had a low iron glass cover for high transmissivity of solar radiation, and polycrystalline silicon solar photovoltaic cells adhered to the absorber. Heat loss coefficient for the FP-PVT collector was measured as 4.1W/m2/K and 3.5W/m2/K for the CPC-PVT solar collector. These solar collectors were tested under steady state conditions using the solar simulator facility at the University of Ulster’s Centre for Sustainable Technologies. The FP-PVT and the CPC-PVT had a combined efficiency of 66.8% and 53.4% respectively producing both heat and power.
Key concepts: Photovoltaic thermal hybrid solar collector, Solar mirror, Photovoltaic system, Solar energy, Nanofluids in solar collectors, Solar cell efficiency, Materials science, Nuclear engineering