1990PubMedRequires access

Regional cerebral blood flow imaging: a quantitative comparison of technetium-99m-HMPAO SPECT with C15O2 PET.

H. G. Gemmell, Noel T. S. Evans, JOHN A. O. BESSON, Dirk Roeda, Joyce E Davidson, M. Dodd, Peter F. Sharp, Francis W. K. Smith, John R. Crawford, Richard Newton

Open publisher page 63 citations

Abstract

The aim of this study was to compare technetium-99m-hexamethylpropyleneamineoxime (99mTc-HMPAO) single-photon emission computed tomography (SPECT) with regional cerebral blood flow (rCBF) imaging using positron emission tomography (PET). As investigation of dementia is likely to be one of the main uses of routine rCBF imaging, 18 demented patients were imaged with both techniques. The PET data were compared quantitatively with three versions of the SPECT data. These were, first, data normalized to the SPECT cerebellar uptake, second, data linearly corrected using the PET cerebellar value and, finally, data Lassen corrected for washout from the high flow areas. Both the linearly-corrected (r = 0.81) and the Lassen-corrected (r = 0.79) HMPAO SPECT data showed good correlation with the PET rCBF data. The relationship between the normalized HMPAO SPECT data and the PET data was nonlinear. It is not yet possible to obtain rCBF values in absolute units from HMPAO SPECT without knowledge of the true rCBF in one reference region for each patient.

About this research paper

What this paper is about

The aim of this study was to compare technetium-99m-hexamethylpropyleneamineoxime (99mTc-HMPAO) single-photon emission computed tomography (SPECT) with regional cerebral blood flow (rCBF) imaging using positron emission tomography (PET). As investigation of dementia is likely to be one of the main uses of routine rCBF imaging, 18 demented patients were imaged with both techniques. The PET data were compared quantitatively with three versions of the SPECT data. These were, first, data normalized to the SPECT cerebellar uptake, second, data linearly corrected using the PET cerebellar value and, finally, data Lassen corrected for washout from the high flow areas. Both the linearly-corrected (r = 0.81) and the Lassen-corrected (r = 0.79) HMPAO SPECT data showed good correlation with the PET rCBF data. The relationship between the normalized HMPAO SPECT data and the PET data was nonlinear. It is not yet possible to obtain rCBF values in absolute units from HMPAO SPECT without knowledge of the true rCBF in one reference region for each patient.

Why it matters

OpenAlex reports 63 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

The aim of this study was to compare technetium-99m-hexamethylpropyleneamineoxime (99mTc-HMPAO) single-photon emission computed tomography (SPECT) with regional cerebral blood flow (rCBF) imaging using positron emission tomography (PET). As investigation of dementia is likely to be one of the main uses of routine rCBF imaging, 18 demented patients were imaged with both techniques. The PET data were compared quantitatively with three versions of the SPECT data. These were, first, data normalized to the SPECT cerebellar uptake, second, data linearly corrected using the PET cerebellar value and, finally, data Lassen corrected for washout from the high flow areas. Both the linearly-corrected (r = 0.81) and the Lassen-corrected (r = 0.79) HMPAO SPECT data showed good correlation with the PET rCBF data. The relationship between the normalized HMPAO SPECT data and the PET data was nonlinear. It is not yet possible to obtain rCBF values in absolute units from HMPAO SPECT without knowledge of the true rCBF in one reference region for each patient.

Key concepts: Nuclear medicine, Cerebral blood flow, Positron emission tomography, Single-photon emission computed tomography, Emission computed tomography, Technetium-99m, Spect imaging, Positron

Related papers

Back to paper searchBrowse research topicsOriginal source
Regional cerebral blood flow imaging: a quantitative comparison of technetium-99m-HMPAO SPECT with C15O2 PET. — Research Paper | ScholarLens