2006Rapid Communications in Mass SpectrometryRequires access

Exact‐mass library for pesticides using a molecular‐feature database

Imma Ferrer, Amadeo R. Fernández‐Alba, Jerry Zweigenbaum, E. Michael Thurman

Open publisher page 76 citations

Abstract

An automated molecular-feature database (MFD) consisting of the exact monoisotopic mass of 100 compounds, at least one exact mass product ion for each compound, and chromatographic retention time were used to identify pesticides in food and water samples. The MFD software compiles a list of accurate mass ions, excludes noise, and compares them with the monoisotopic exact masses in the database. The screening criteria consisted of +/-5 ppm accurate mass window, +/-0.2 min retention time window, and a minimum 1000 counts (signal-to-noise (S/N) ratio of approximately 10:1). The limit of detection for 100 tested compounds varied from <0.01 mg/kg for 72% of the compounds to <0.1 mg/kg for 95% of the compounds. The MFD search was useful for rapid screening and identification of pesticides in food and water, as shown in actual samples. The combined use of accurate mass and chromatographic retention time eliminated false positives in the automated analysis. The major weakness of the MFD is matrix interferences and loss of mass accuracy. Strengths of the MFD include rapid screening of 100 compounds at sensitive levels compared with a manual approach and the ease of use of the library for any accurate mass spectrometer instrumentation capable of routine sub-5-ppm mass accuracy.

About this research paper

What this paper is about

An automated molecular-feature database (MFD) consisting of the exact monoisotopic mass of 100 compounds, at least one exact mass product ion for each compound, and chromatographic retention time were used to identify pesticides in food and water samples. The MFD software compiles a list of accurate mass ions, excludes noise, and compares them with the monoisotopic exact masses in the database. The screening criteria consisted of +/-5 ppm accurate mass window, +/-0.2 min retention time window, and a minimum 1000 counts (signal-to-noise (S/N) ratio of approximately 10:1). The limit of detection for 100 tested compounds varied from <0.01 mg/kg for 72% of the compounds to <0.1 mg/kg for 95% of the compounds. The MFD search was useful for rapid screening and identification of pesticides in food and water, as shown in actual samples. The combined use of accurate mass and chromatographic retention time eliminated false positives in the automated analysis. The major weakness of the MFD is matrix interferences and loss of mass accuracy. Strengths of the MFD include rapid screening of 100 compounds at sensitive levels compared with a manual approach and the ease of use of the library for any accurate mass spectrometer instrumentation capable of routine sub-5-ppm mass accuracy.

Why it matters

OpenAlex reports 76 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

An automated molecular-feature database (MFD) consisting of the exact monoisotopic mass of 100 compounds, at least one exact mass product ion for each compound, and chromatographic retention time were used to identify pesticides in food and water samples. The MFD software compiles a list of accurate mass ions, excludes noise, and compares them with the monoisotopic exact masses in the database. The screening criteria consisted of +/-5 ppm accurate mass window, +/-0.2 min retention time window, and a minimum 1000 counts (signal-to-noise (S/N) ratio of approximately 10:1). The limit of detection for 100 tested compounds varied from <0.01 mg/kg for 72% of the compounds to <0.1 mg/kg for 95% of the compounds. The MFD search was useful for rapid screening and identification of pesticides in food and water, as shown in actual samples. The combined use of accurate mass and chromatographic retention time eliminated false positives in the automated analysis. The major weakness of the MFD is matrix interferences and loss of mass accuracy. Strengths of the MFD include rapid screening of 100 compounds at sensitive levels compared with a manual approach and the ease of use of the library for any accurate mass spectrometer instrumentation capable of routine sub-5-ppm mass accuracy.

Key concepts: Chemistry, Feature (linguistics), Pesticide, Database, Chromatography, Computer science, Agronomy, Linguistics

Related papers

Back to paper searchBrowse research topicsOriginal source
Exact‐mass library for pesticides using a molecular‐feature database — Research Paper | ScholarLens