2008American Journal of Industrial MedicineOpen access

Extended high‐frequency audiometry and noise induced hearing loss in cement workers

Giuseppina Somma, Antonio Pietroiusti, Andrea Magrini, Luca Coppeta, Carla Ancona, Stefano Gardi, Marco Messina, Antonio Bergamaschi

Open full text 79 citations

Abstract

BACKGROUND: It has been suggested that extended high-frequency audiometry (EHFA) might be more sensitive than conventional audiometry in detecting early signs of hearing impairment. However, this technique has not been adequately tested in an occupational environment. We therefore investigated the usefulness of this method in noise-exposed workers. METHODS: We compared conventional frequency audiometry (0.25-8 kHz) and EHFA (9-18 kHz) in 184 noise-exposed and 98 non-noise-exposed workers. RESULTS: Both methods showed significantly higher threshold levels (P < 0.05) in noise-exposed workers for most of the tested frequencies; however, the differences were more marked for EHFA, especially in young exposed workers. Significant differences in the EHF range were detected also in the subgroup of noise-exposed workers with normal findings at conventional audiometry. Stepwise regression analysis showed that in 21- to 40-year-old workers the noise effect was largely predominant at both conventional audiometry and EHFA, whereas in older subjects the noise effect was predominant up to 6 kHz frequency, the effect of age being significantly greater at higher frequencies. CONCLUSIONS: These data indicate that EHFA is more sensitive than conventional audiometry in detecting noise induced hearing loss. However, hearing loss in the EHF range seems an age-dependent phenomenon with progression into the lower speech range frequencies with increasing age. These changes seem to be accentuated in the early years by noise exposure, suggesting that EHFA could represent a useful preventive measure in young exposed workers.

Open-access reader

About this research paper

What this paper is about

BACKGROUND: It has been suggested that extended high-frequency audiometry (EHFA) might be more sensitive than conventional audiometry in detecting early signs of hearing impairment. However, this technique has not been adequately tested in an occupational environment. We therefore investigated the usefulness of this method in noise-exposed workers. METHODS: We compared conventional frequency audiometry (0.25-8 kHz) and EHFA (9-18 kHz) in 184 noise-exposed and 98 non-noise-exposed workers. RESULTS: Both methods showed significantly higher threshold levels (P < 0.05) in noise-exposed workers for most of the tested frequencies; however, the differences were more marked for EHFA, especially in young exposed workers. Significant differences in the EHF range were detected also in the subgroup of noise-exposed workers with normal findings at conventional audiometry. Stepwise regression analysis showed that in 21- to 40-year-old workers the noise effect was largely predominant at both conventional audiometry and EHFA, whereas in older subjects the noise effect was predominant up to 6 kHz frequency, the effect of age being significantly greater at higher frequencies. CONCLUSIONS: These data indicate that EHFA is more sensitive than conventional audiometry in detecting noise induced hearing loss. However, hearing loss in the EHF range seems an age-dependent phenomenon with progression into the lower speech range frequencies with increasing age. These changes seem to be accentuated in the early years by noise exposure, suggesting that EHFA could represent a useful preventive measure in young exposed workers.

Why it matters

OpenAlex reports 79 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

BACKGROUND: It has been suggested that extended high-frequency audiometry (EHFA) might be more sensitive than conventional audiometry in detecting early signs of hearing impairment. However, this technique has not been adequately tested in an occupational environment. We therefore investigated the usefulness of this method in noise-exposed workers. METHODS: We compared conventional frequency audiometry (0.25-8 kHz) and EHFA (9-18 kHz) in 184 noise-exposed and 98 non-noise-exposed workers. RESULTS: Both methods showed significantly higher threshold levels (P < 0.05) in noise-exposed workers for most of the tested frequencies; however, the differences were more marked for EHFA, especially in young exposed workers. Significant differences in the EHF range were detected also in the subgroup of noise-exposed workers with normal findings at conventional audiometry. Stepwise regression analysis showed that in 21- to 40-year-old workers the noise effect was largely predominant at both conventional audiometry and EHFA, whereas in older subjects the noise effect was predominant up to 6 kHz frequency, the effect of age being significantly greater at higher frequencies. CONCLUSIONS: These data indicate that EHFA is more sensitive than conventional audiometry in detecting noise induced hearing loss. However, hearing loss in the EHF range seems an age-dependent phenomenon with progression into the lower speech range frequencies with increasing age. These changes seem to be accentuated in the early years by noise exposure, suggesting that EHFA could represent a useful preventive measure in young exposed workers.

Key concepts: Audiometry, Medicine, Audiology, Hearing loss, Noise (video), Noise exposure, Noise-induced hearing loss, Pure tone audiometry

Related papers

Back to paper searchBrowse research topicsOriginal source
Extended high‐frequency audiometry and noise induced hearing loss in cement workers — Research Paper | ScholarLens