2008Journal of the Peripheral Nervous SystemOpen access

High‐ and low‐frequency transcutaneous electrical nerve stimulation delay sciatic nerve regeneration after crush lesion in the mouse

Abrahão Fontes Baptista, Joyce R. S. Gomes, Júlia Teixeira Oliveira, Soraia Moreira Garzedim Santos, Marcos A. Vannier‐Santos, Ana Maria Blanco Martinez

Open full text 75 citations

Abstract

The stimulation of peripheral nerve regeneration has been studied in different ways, including the use of electrical fields. The capacity of this modality to enhance nerve regeneration is influenced by the parameters used, including current type, frequency, intensity, and means of administration. Transcutaneous electrical nerve stimulation (TENS) is a frequently used form of administering electrical current to the body, but its effects on peripheral nerve regeneration are not known. This study assessed the influence of TENS on sciatic nerve regeneration, using a model of crush lesion in the mouse. Mice were stimulated 30 min a day, 5 days a week, for 5 weeks with both high- (100 Hz) and low- (4 Hz) frequency TENS. Control animals had the sciatic nerve crushed but were not stimulated. Assessment was performed weekly by functional analysis using the Static Sciatic Index for the mouse and at the end of the experiment by light and electron microscopy. The results showed that although there were no differences between the groups regarding the Static Sciatic Index values, TENS led to nerves with morphological signs of impaired regeneration. At light microscopy level, TENS nerves presented more axons with dark axoplasm, signs of edema, and a less organized cytoarchitecture. Electronmicrographs showed fewer and thinner thick myelinated fibers and increased number of Schwann cell nuclei. Myelinated axon diameters and density and diameter of nonmyelinated fibers were not affected by TENS, leading to the conclusion that this regimen of electrical stimulation leads to a delayed regeneration after a crush lesion of the sciatic nerve in the mouse. All these effects were more pronounced on high-frequency TENS nerves.

About this research paper

What this paper is about

The stimulation of peripheral nerve regeneration has been studied in different ways, including the use of electrical fields. The capacity of this modality to enhance nerve regeneration is influenced by the parameters used, including current type, frequency, intensity, and means of administration. Transcutaneous electrical nerve stimulation (TENS) is a frequently used form of administering electrical current to the body, but its effects on peripheral nerve regeneration are not known. This study assessed the influence of TENS on sciatic nerve regeneration, using a model of crush lesion in the mouse. Mice were stimulated 30 min a day, 5 days a week, for 5 weeks with both high- (100 Hz) and low- (4 Hz) frequency TENS. Control animals had the sciatic nerve crushed but were not stimulated. Assessment was performed weekly by functional analysis using the Static Sciatic Index for the mouse and at the end of the experiment by light and electron microscopy. The results showed that although there were no differences between the groups regarding the Static Sciatic Index values, TENS led to nerves with morphological signs of impaired regeneration. At light microscopy level, TENS nerves presented more axons with dark axoplasm, signs of edema, and a less organized cytoarchitecture. Electronmicrographs showed fewer and thinner thick myelinated fibers and increased number of Schwann cell nuclei. Myelinated axon diameters and density and diameter of nonmyelinated fibers were not affected by TENS, leading to the conclusion that this regimen of electrical stimulation leads to a delayed regeneration after a crush lesion of the sciatic nerve in the mouse. All these effects were more pronounced on high-frequency TENS nerves.

Why it matters

OpenAlex reports 75 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

The stimulation of peripheral nerve regeneration has been studied in different ways, including the use of electrical fields. The capacity of this modality to enhance nerve regeneration is influenced by the parameters used, including current type, frequency, intensity, and means of administration. Transcutaneous electrical nerve stimulation (TENS) is a frequently used form of administering electrical current to the body, but its effects on peripheral nerve regeneration are not known. This study assessed the influence of TENS on sciatic nerve regeneration, using a model of crush lesion in the mouse. Mice were stimulated 30 min a day, 5 days a week, for 5 weeks with both high- (100 Hz) and low- (4 Hz) frequency TENS. Control animals had the sciatic nerve crushed but were not stimulated. Assessment was performed weekly by functional analysis using the Static Sciatic Index for the mouse and at the end of the experiment by light and electron microscopy. The results showed that although there were no differences between the groups regarding the Static Sciatic Index values, TENS led to nerves with morphological signs of impaired regeneration. At light microscopy level, TENS nerves presented more axons with dark axoplasm, signs of edema, and a less organized cytoarchitecture. Electronmicrographs showed fewer and thinner thick myelinated fibers and increased number of Schwann cell nuclei. Myelinated axon diameters and density and diameter of nonmyelinated fibers were not affected by TENS, leading to the conclusion that this regimen of electrical stimulation leads to a delayed regeneration after a crush lesion of the sciatic nerve in the mouse. All these effects were more pronounced on high-frequency TENS nerves.

Key concepts: Sciatic nerve, Regeneration (biology), Axon, Stimulation, Lesion, Medicine, Transcutaneous electrical nerve stimulation, Anatomy

Related papers

Back to paper searchBrowse research topicsOriginal source
High‐ and low‐frequency transcutaneous electrical nerve stimulation delay sciatic nerve regeneration after crush lesion in the mouse — Research Paper | ScholarLens