The dose-response relationship between in-ear occupational noise exposure and hearing loss
Peter Rabinowitz, Deron Galusha, Christine Dixon-Ernst, Jane E. Clougherty, Richard L. Neitzel
Abstract
Peter Rabinowitz, Deron Galusha, Christine Dixon-Ernst, Jane E. Clougherty, Richard L. Neitzel
Abstract
OBJECTIVES: Current understanding of the dose-response relationship between occupational noise and hearing loss is based on cross-sectional studies prior to the widespread use of hearing protection, and with limited data regarding noise exposures below 85 dBA. We report on the hearing loss experience of a unique cohort of industrial workers, with daily monitoring of noise inside of hearing protection devices. METHODS: At an industrial facility, workers exhibiting accelerated hearing loss were enrolled in a mandatory programme to monitor daily noise exposures inside of hearing protection. We compared these noise measurements (as time-weighted LAVG) to interval rates of high-frequency hearing loss over a 6-year period using a mixed-effects model, adjusting for potential confounders. RESULTS: Workers' high-frequency hearing levels at study inception averaged more than 40 dB Hearing threshold level (HTL). Most noise exposures were less than 85 dBA (mean LAVG 76 dBA, IQR 74-80 dBA). We found no statistical relationship between LAvg and high-frequency hearing loss (p=0.53). Using a metric for monthly maximum noise exposure did not improve model fit. CONCLUSIONS: At-ear noise exposures below 85 dBA did not show an association with risk of high-frequency hearing loss among workers with substantial past noise exposure and hearing loss at baseline. Therefore, effective noise control to below 85 dBA may lead to significant reduction in occupational hearing loss risk in such individuals. Further research is needed on the dose-response relationship of noise and hearing loss in individuals with normal hearing and little prior noise exposure.
OpenAlex reports 27 citations for this work. Citation counts describe recorded attention and do not establish research quality.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
OBJECTIVES: Current understanding of the dose-response relationship between occupational noise and hearing loss is based on cross-sectional studies prior to the widespread use of hearing protection, and with limited data regarding noise exposures below 85 dBA. We report on the hearing loss experience of a unique cohort of industrial workers, with daily monitoring of noise inside of hearing protection devices. METHODS: At an industrial facility, workers exhibiting accelerated hearing loss were enrolled in a mandatory programme to monitor daily noise exposures inside of hearing protection. We compared these noise measurements (as time-weighted LAVG) to interval rates of high-frequency hearing loss over a 6-year period using a mixed-effects model, adjusting for potential confounders. RESULTS: Workers' high-frequency hearing levels at study inception averaged more than 40 dB Hearing threshold level (HTL). Most noise exposures were less than 85 dBA (mean LAVG 76 dBA, IQR 74-80 dBA). We found no statistical relationship between LAvg and high-frequency hearing loss (p=0.53). Using a metric for monthly maximum noise exposure did not improve model fit. CONCLUSIONS: At-ear noise exposures below 85 dBA did not show an association with risk of high-frequency hearing loss among workers with substantial past noise exposure and hearing loss at baseline. Therefore, effective noise control to below 85 dBA may lead to significant reduction in occupational hearing loss risk in such individuals. Further research is needed on the dose-response relationship of noise and hearing loss in individuals with normal hearing and little prior noise exposure.
Key concepts: Fibronectin, Laminin, Integrin, Extracellular matrix, Cell culture, Lung cancer, Cancer research, Cell adhesion molecule