2003Revista de Saúde PúblicaOpen access

Performance of an immunochromatography test for vivax malaria in the Amazon region, Brazil

Alberto Ferreira Figueiredo Filho, Maria Cristina Figueredo, José Maria Nascimento, Vanja Suely Pachiano Calvosa, Marinete Marins Póvoa, Ricardo Luiz Dantas Machado

Open full text 12 citations

Abstract

The study was carried out to evaluate the diagnostic performance of the ICT malaria Pf/Pv test for vivax malaria diagnosis in Bel m, Amazon region, Brazil. The results of blood malaria parasites examination using an immunochromatography test were compared with thick blood film (TBF) examination. It was also evaluated the performance of this test storaged at three different temperatures (25 degree C, 30 degree C, and 37 degree C) for 24 hours before use. Overall sensitivity of ICT Pf/Pv was 61.8% with a specificity of 100%, positive and negative predictive value of 100% and 71.8%, respectively and accuracy of 80.6%. The test sensitivity was independent of the parasite density. This test needs to be further reviewed in order to have better performance for P. vivax malaria diagnosis.

Open-access reader

About this research paper

What this paper is about

The study was carried out to evaluate the diagnostic performance of the ICT malaria Pf/Pv test for vivax malaria diagnosis in Bel m, Amazon region, Brazil. The results of blood malaria parasites examination using an immunochromatography test were compared with thick blood film (TBF) examination. It was also evaluated the performance of this test storaged at three different temperatures (25 degree C, 30 degree C, and 37 degree C) for 24 hours before use. Overall sensitivity of ICT Pf/Pv was 61.8% with a specificity of 100%, positive and negative predictive value of 100% and 71.8%, respectively and accuracy of 80.6%. The test sensitivity was independent of the parasite density. This test needs to be further reviewed in order to have better performance for P. vivax malaria diagnosis.

Why it matters

OpenAlex reports 12 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

The study was carried out to evaluate the diagnostic performance of the ICT malaria Pf/Pv test for vivax malaria diagnosis in Bel m, Amazon region, Brazil. The results of blood malaria parasites examination using an immunochromatography test were compared with thick blood film (TBF) examination. It was also evaluated the performance of this test storaged at three different temperatures (25 degree C, 30 degree C, and 37 degree C) for 24 hours before use. Overall sensitivity of ICT Pf/Pv was 61.8% with a specificity of 100%, positive and negative predictive value of 100% and 71.8%, respectively and accuracy of 80.6%. The test sensitivity was independent of the parasite density. This test needs to be further reviewed in order to have better performance for P. vivax malaria diagnosis.

Key concepts: Vivax malaria, Malaria, Amazon rainforest, Diagnosis of malaria, Plasmodium vivax, Rapid diagnostic test, Blood film, Blood smear

Related papers

Back to paper searchBrowse research topicsOriginal source
Performance of an immunochromatography test for vivax malaria in the Amazon region, Brazil — Research Paper | ScholarLens