2002Unpublished venueRequires access

Superconducting cavity tuner performance at CEBAF

J. R. Marshall, J. Preble, W. Schneider

Open publisher page 0 citations

Abstract

At the Continuous Electron Beam Accelerator Facility (CEBAF), a 4 GeV multipass CW electron beam is to be accelerated by 338 SRF, 5-cell niobium cavities operating at a resonant frequency of 1497 MHz. Eight cavities arranged as four pairs comprise a cryomodule, a cryogenically isolated linac subdivision. The frequency is controlled by a mechanical tuner attached to the first and fifth cell of the cavity which elastically deforms the cavity and thereby alters its resonant frequency. The tuner is driven by a stepper motor mounted external to the cryomodule that transfers torque through two rotary feedthroughs. A linear variable differential transducer (LVDT) mounted on the tuner monitors the displacement. Two limit switches interlock the movement beyond a 400 kHz bandwidth. Since the cavity has a loaded Q of 6.6x10/sup 6/, the control system must maintain the frequency of the cavity to within /spl plusmn/50 Hz of the drive frequency for efficient coupling. This requirement is somewhat difficult to achieve since the difference in thermal contractions of the cavity and the tuner creates a frequency hysteresis of approximately 10 kHz. The cavity is also subject to frequency shifts due to pressure fluctuations of the helium bath as well as radiation pressure. This requires that each cavity be characterized in terms of frequency change as a function of applied motor steps to allow proper tuning operations. This paper describes the electrical and mechanical performance of the cavity tuner during the commissioning and operation of the cryomodules manufactured to date.>

About this research paper

What this paper is about

At the Continuous Electron Beam Accelerator Facility (CEBAF), a 4 GeV multipass CW electron beam is to be accelerated by 338 SRF, 5-cell niobium cavities operating at a resonant frequency of 1497 MHz. Eight cavities arranged as four pairs comprise a cryomodule, a cryogenically isolated linac subdivision. The frequency is controlled by a mechanical tuner attached to the first and fifth cell of the cavity which elastically deforms the cavity and thereby alters its resonant frequency. The tuner is driven by a stepper motor mounted external to the cryomodule that transfers torque through two rotary feedthroughs. A linear variable differential transducer (LVDT) mounted on the tuner monitors the displacement. Two limit switches interlock the movement beyond a 400 kHz bandwidth. Since the cavity has a loaded Q of 6.6x10/sup 6/, the control system must maintain the frequency of the cavity to within /spl plusmn/50 Hz of the drive frequency for efficient coupling. This requirement is somewhat difficult to achieve since the difference in thermal contractions of the cavity and the tuner creates a frequency hysteresis of approximately 10 kHz. The cavity is also subject to frequency shifts due to pressure fluctuations of the helium bath as well as radiation pressure. This requires that each cavity be characterized in terms of frequency change as a function of applied motor steps to allow proper tuning operations. This paper describes the electrical and mechanical performance of the cavity tuner during the commissioning and operation of the cryomodules manufactured to date.>

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

At the Continuous Electron Beam Accelerator Facility (CEBAF), a 4 GeV multipass CW electron beam is to be accelerated by 338 SRF, 5-cell niobium cavities operating at a resonant frequency of 1497 MHz. Eight cavities arranged as four pairs comprise a cryomodule, a cryogenically isolated linac subdivision. The frequency is controlled by a mechanical tuner attached to the first and fifth cell of the cavity which elastically deforms the cavity and thereby alters its resonant frequency. The tuner is driven by a stepper motor mounted external to the cryomodule that transfers torque through two rotary feedthroughs. A linear variable differential transducer (LVDT) mounted on the tuner monitors the displacement. Two limit switches interlock the movement beyond a 400 kHz bandwidth. Since the cavity has a loaded Q of 6.6x10/sup 6/, the control system must maintain the frequency of the cavity to within /spl plusmn/50 Hz of the drive frequency for efficient coupling. This requirement is somewhat difficult to achieve since the difference in thermal contractions of the cavity and the tuner creates a frequency hysteresis of approximately 10 kHz. The cavity is also subject to frequency shifts due to pressure fluctuations of the helium bath as well as radiation pressure. This requires that each cavity be characterized in terms of frequency change as a function of applied motor steps to allow proper tuning operations. This paper describes the electrical and mechanical performance of the cavity tuner during the commissioning and operation of the cryomodules manufactured to date.>

Key concepts: Tuner, Superconducting radio frequency, Linear particle accelerator, Physics, Niobium, Varicap, Nuclear magnetic resonance, Electrical engineering

Related papers

Back to paper searchBrowse research topicsOriginal source
Superconducting cavity tuner performance at CEBAF — Research Paper | ScholarLens