2007PubMedRequires access

Kinetic study of antibodies (IgG, IgA) to Chlamydia trachomatis: importance of IgA antibody in screening test for C. trachomatis infection by peptide-based enzyme immunosorbent assay.

Teruko Komoda

Open publisher page 18 citations

Abstract

To assess the importance of only IgA antibody positivity in the peptide-based ELISA (P-ELISA) examination of kinetic behaviors of antibodies (IgA, IgG) to Chlamydia trachomatis, 426 sera from 52 follow-up antigen-positive patients were assayed. In part, a microimmunofluorescence (MIF) test and an immunoblot (IB) assay were also used for confirmation. The results showed that the positivity rates of IgA and IgG antibodies were 82.7 and 96.2%, respectively, at the first testing. One patient had both IgA- and IgG-negative antibodies at the first testing, but this became only IgA-positive and then IgG-positive. The patient was co-infected with Candida albicans and C. trachomatis, and saw a gynecologist for the symptom of itching. Although the major outer membrane protein was negative in IB assay, the results of the MIF test and absorption experiments were positive. MIF titers for IgA and IgG antibodies to C. pneumoniae were <1:8 and 1:32, respectively, at the peak level of P-ELISA. These findings seem to suggest that when only the IgA antibody is detected by P-ELISA, C. trachomatis infection may be present at an early stage, so confirmation via testing for C. trachomatis is needed.

About this research paper

What this paper is about

To assess the importance of only IgA antibody positivity in the peptide-based ELISA (P-ELISA) examination of kinetic behaviors of antibodies (IgA, IgG) to Chlamydia trachomatis, 426 sera from 52 follow-up antigen-positive patients were assayed. In part, a microimmunofluorescence (MIF) test and an immunoblot (IB) assay were also used for confirmation. The results showed that the positivity rates of IgA and IgG antibodies were 82.7 and 96.2%, respectively, at the first testing. One patient had both IgA- and IgG-negative antibodies at the first testing, but this became only IgA-positive and then IgG-positive. The patient was co-infected with Candida albicans and C. trachomatis, and saw a gynecologist for the symptom of itching. Although the major outer membrane protein was negative in IB assay, the results of the MIF test and absorption experiments were positive. MIF titers for IgA and IgG antibodies to C. pneumoniae were <1:8 and 1:32, respectively, at the peak level of P-ELISA. These findings seem to suggest that when only the IgA antibody is detected by P-ELISA, C. trachomatis infection may be present at an early stage, so confirmation via testing for C. trachomatis is needed.

Why it matters

OpenAlex reports 18 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

To assess the importance of only IgA antibody positivity in the peptide-based ELISA (P-ELISA) examination of kinetic behaviors of antibodies (IgA, IgG) to Chlamydia trachomatis, 426 sera from 52 follow-up antigen-positive patients were assayed. In part, a microimmunofluorescence (MIF) test and an immunoblot (IB) assay were also used for confirmation. The results showed that the positivity rates of IgA and IgG antibodies were 82.7 and 96.2%, respectively, at the first testing. One patient had both IgA- and IgG-negative antibodies at the first testing, but this became only IgA-positive and then IgG-positive. The patient was co-infected with Candida albicans and C. trachomatis, and saw a gynecologist for the symptom of itching. Although the major outer membrane protein was negative in IB assay, the results of the MIF test and absorption experiments were positive. MIF titers for IgA and IgG antibodies to C. pneumoniae were <1:8 and 1:32, respectively, at the peak level of P-ELISA. These findings seem to suggest that when only the IgA antibody is detected by P-ELISA, C. trachomatis infection may be present at an early stage, so confirmation via testing for C. trachomatis is needed.

Key concepts: Chlamydia trachomatis, Antibody, Immunology, Titer, Antigen, Chlamydia, Immunoglobulin A, Chlamydiaceae

Related papers

Back to paper searchBrowse research topicsOriginal source
Kinetic study of antibodies (IgG, IgA) to Chlamydia trachomatis: importance of IgA antibody in screening test for C. trachomatis infection by peptide-based enzyme immunosorbent assay. — Research Paper | ScholarLens