2009Journal of the Chilean Chemical SocietyOpen access

PREPARATION OF MANGANESE DIOXIDE MODIFIED GLASSY CARBON ELECTRODE BY A NOVEL FILM PLATING/CYCLIC VOLTAMMETRY METHOD FOR H(2)0(2) DETECTION

Wen-Zhi Le, You‐Qin Liu, Guangqi Hu

Open full text 23 citations

Abstract

Manganese dioxide modified glassy carbon electrode (MnO 2 /GC) was prepared by a novel film plating/cyclic voltammetry method for the determination of H 2 O 2 .A manganese film was first cathodically deposited on the surface of glassy carbon electrode from MnCl 2 solution at the potential of -1.4 V versus Ag/ AgCl (satd.KCl), and then a well defined manganese dioxide was deposited on the surface of glassy carbon electrode by cyclic voltammetry at potential range -0.6 ~ 0.6 V, scan rate 100 mV s -1 in 0.1 mol L -1 NaOH solution.The resulted modified electrode was characterized by cyclic voltammetry and scanning electron microscopy (SEM), which showed excellent electrocatalytic activity for the oxidation of H 2 O 2 .The chronoamperometric detection of H 2 O 2 was carried out at 0.6 V in phosphate buffer solution pH 7.38 containing 0.1 mol L -1 KCl and the linear relationship of response current on H 2 O 2 concentration was obtained in the range from 4.1×10 -10 to 1×10 -4 mol L -1 with a minimum detectable concentration of 3×10 -10 mol L -1 [S/N (signal noise ratio) = 3].The response time of the electrode to achieve 95% of the steady-state current was < 2 s.No measurable reduction in analytical performance of the modified electrode was found by storing the electrode in ambient conditions for 30 days.This modified electrode has many advantages such as simple preparation procedure, remarkable catalytic activity, good reproducibility and long term stability of signal response during hydrogen peroxide oxidation.The deposition of manganese dioxide on the surface of GC appears to be a highly efficient method for the development of a new class of sensitive, stable and reproducible hydrogen peroxide electrochemical sensor.

Open-access reader

About this research paper

What this paper is about

Manganese dioxide modified glassy carbon electrode (MnO 2 /GC) was prepared by a novel film plating/cyclic voltammetry method for the determination of H 2 O 2 .A manganese film was first cathodically deposited on the surface of glassy carbon electrode from MnCl 2 solution at the potential of -1.4 V versus Ag/ AgCl (satd.KCl), and then a well defined manganese dioxide was deposited on the surface of glassy carbon electrode by cyclic voltammetry at potential range -0.6 ~ 0.6 V, scan rate 100 mV s -1 in 0.1 mol L -1 NaOH solution.The resulted modified electrode was characterized by cyclic voltammetry and scanning electron microscopy (SEM), which showed excellent electrocatalytic activity for the oxidation of H 2 O 2 .The chronoamperometric detection of H 2 O 2 was carried out at 0.6 V in phosphate buffer solution pH 7.38 containing 0.1 mol L -1 KCl and the linear relationship of response current on H 2 O 2 concentration was obtained in the range from 4.1×10 -10 to 1×10 -4 mol L -1 with a minimum detectable concentration of 3×10 -10 mol L -1 [S/N (signal noise ratio) = 3].The response time of the electrode to achieve 95% of the steady-state current was < 2 s.No measurable reduction in analytical performance of the modified electrode was found by storing the electrode in ambient conditions for 30 days.This modified electrode has many advantages such as simple preparation procedure, remarkable catalytic activity, good reproducibility and long term stability of signal response during hydrogen peroxide oxidation.The deposition of manganese dioxide on the surface of GC appears to be a highly efficient method for the development of a new class of sensitive, stable and reproducible hydrogen peroxide electrochemical sensor.

Why it matters

OpenAlex reports 23 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Manganese dioxide modified glassy carbon electrode (MnO 2 /GC) was prepared by a novel film plating/cyclic voltammetry method for the determination of H 2 O 2 .A manganese film was first cathodically deposited on the surface of glassy carbon electrode from MnCl 2 solution at the potential of -1.4 V versus Ag/ AgCl (satd.KCl), and then a well defined manganese dioxide was deposited on the surface of glassy carbon electrode by cyclic voltammetry at potential range -0.6 ~ 0.6 V, scan rate 100 mV s -1 in 0.1 mol L -1 NaOH solution.The resulted modified electrode was characterized by cyclic voltammetry and scanning electron microscopy (SEM), which showed excellent electrocatalytic activity for the oxidation of H 2 O 2 .The chronoamperometric detection of H 2 O 2 was carried out at 0.6 V in phosphate buffer solution pH 7.38 containing 0.1 mol L -1 KCl and the linear relationship of response current on H 2 O 2 concentration was obtained in the range from 4.1×10 -10 to 1×10 -4 mol L -1 with a minimum detectable concentration of 3×10 -10 mol L -1 [S/N (signal noise ratio) = 3].The response time of the electrode to achieve 95% of the steady-state current was < 2 s.No measurable reduction in analytical performance of the modified electrode was found by storing the electrode in ambient conditions for 30 days.This modified electrode has many advantages such as simple preparation procedure, remarkable catalytic activity, good reproducibility and long term stability of signal response during hydrogen peroxide oxidation.The deposition of manganese dioxide on the surface of GC appears to be a highly efficient method for the development of a new class of sensitive, stable and reproducible hydrogen peroxide electrochemical sensor.

Key concepts: Cyclic voltammetry, Manganese, Glassy carbon, Carbon dioxide, Plating (geology), Materials science, Electrode, Inorganic chemistry

Related papers

Back to paper searchBrowse research topicsOriginal source
PREPARATION OF MANGANESE DIOXIDE MODIFIED GLASSY CARBON ELECTRODE BY A NOVEL FILM PLATING/CYCLIC VOLTAMMETRY METHOD FOR H(2)0(2) DETECTION — Research Paper | ScholarLens