2011•Proceedings of the Institution of Mechanical Engineers Part A Journal of Power and EnergyRequires access

Research and development of a semi-hermetic reciprocating compressor for transcritical CO 2 refrigeration cycle

Yuegeng Ma, B Zhang, Yunho Hwang, Xueyuan Peng, Ziwen Xing

Open publisher page 8 citations

Abstract

A semi-hermetic reciprocating compressor was designed and developed for the transcritical carbon dioxide (CO 2 ) refrigeration cycle. In addition, a mathematical model was established to simulate the thermodynamic process in this transcritical CO 2 compressor. The internal leakage, heat transfer, and flows through the suction/discharge valves together with the valve motion were taken into account in the model. In order to evaluate the overall performance of the developed compressor, a test rig was built to measure the volumetric efficiency, isentropic efficiency, and coefficient of performance (COP), and also recorded the pressure—volume diagram. The calculated indicated power deviated by 4.16 per cent from the measured one, and the maximum deviations of the isentropic and volumetric efficiencies were −2.86 per cent and 4.87 per cent, respectively. Both the calculated and measured data showed that the compressor had a cooling COP of 2.0—3.2. As the pressure ratio increased from 2.3 to 3.5, the volumetric and isentropic efficiencies ranged from 0.70 to 0.86 and from 0.62 to 0.66, respectively. The recorded p— V diagram indicated that the power losses associated with the suction and discharge processes accounted for 4.6 per cent and 6.8 per cent of the total indicated power, respectively. The validated model can be used to investigate the thermodynamic process of the reciprocating CO 2 compressor with the aim of enhancing the compressor efficiency.

About this research paper

What this paper is about

A semi-hermetic reciprocating compressor was designed and developed for the transcritical carbon dioxide (CO 2 ) refrigeration cycle. In addition, a mathematical model was established to simulate the thermodynamic process in this transcritical CO 2 compressor. The internal leakage, heat transfer, and flows through the suction/discharge valves together with the valve motion were taken into account in the model. In order to evaluate the overall performance of the developed compressor, a test rig was built to measure the volumetric efficiency, isentropic efficiency, and coefficient of performance (COP), and also recorded the pressure—volume diagram. The calculated indicated power deviated by 4.16 per cent from the measured one, and the maximum deviations of the isentropic and volumetric efficiencies were −2.86 per cent and 4.87 per cent, respectively. Both the calculated and measured data showed that the compressor had a cooling COP of 2.0—3.2. As the pressure ratio increased from 2.3 to 3.5, the volumetric and isentropic efficiencies ranged from 0.70 to 0.86 and from 0.62 to 0.66, respectively. The recorded p— V diagram indicated that the power losses associated with the suction and discharge processes accounted for 4.6 per cent and 6.8 per cent of the total indicated power, respectively. The validated model can be used to investigate the thermodynamic process of the reciprocating CO 2 compressor with the aim of enhancing the compressor efficiency.

Why it matters

OpenAlex reports 8 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

A semi-hermetic reciprocating compressor was designed and developed for the transcritical carbon dioxide (CO 2 ) refrigeration cycle. In addition, a mathematical model was established to simulate the thermodynamic process in this transcritical CO 2 compressor. The internal leakage, heat transfer, and flows through the suction/discharge valves together with the valve motion were taken into account in the model. In order to evaluate the overall performance of the developed compressor, a test rig was built to measure the volumetric efficiency, isentropic efficiency, and coefficient of performance (COP), and also recorded the pressure—volume diagram. The calculated indicated power deviated by 4.16 per cent from the measured one, and the maximum deviations of the isentropic and volumetric efficiencies were −2.86 per cent and 4.87 per cent, respectively. Both the calculated and measured data showed that the compressor had a cooling COP of 2.0—3.2. As the pressure ratio increased from 2.3 to 3.5, the volumetric and isentropic efficiencies ranged from 0.70 to 0.86 and from 0.62 to 0.66, respectively. The recorded p— V diagram indicated that the power losses associated with the suction and discharge processes accounted for 4.6 per cent and 6.8 per cent of the total indicated power, respectively. The validated model can be used to investigate the thermodynamic process of the reciprocating CO 2 compressor with the aim of enhancing the compressor efficiency.

Key concepts: Reciprocating compressor, Isentropic process, Gas compressor, Thermodynamics, Transcritical cycle, Refrigeration, Discharge pressure, Cooling capacity

Related papers

Back to paper searchBrowse research topicsOriginal source
Research and development of a semi-hermetic reciprocating compressor for transcritical CO 2 refrigeration cycle — Research Paper | ScholarLens