2014Medical Science MonitorOpen access

Mechanical Properties of Cranial Bones and Sutures in 1–2-Year-Old Infants

Yijiu Chen

Open full text 41 citations

Abstract

BACKGROUND: The mechanical properties of 1-2-year-old pediatric cranial bones and sutures and their influential factors were studied to better understand how the pediatric calvarium reacts to loading. MATERIAL AND METHODS: Cranial bone and suture specimens were extracted from seven fresh-frozen human infant cadavers (1.5±0.5 years old). Eight specimens were obtained from each subject: two frontal bones, two parietal bones, two sagittal suture samples, and two coronal suture samples. The specimens were tested in a three-point bend setup at 1.5 mm/s. The mechanical properties, such as ultimate stress, elastic modulus, and ultimate strain, were calculated for each specimen. RESULTS: The ultimate stress and elastic modulus of the frontal bone were higher than those of the parietal bone (P<0.05). No differences were found between the coronal and sagittal sutures in ultimate stress, elastic modulus, or ultimate strain (P>0.05). The ultimate stress and elastic modulus of the frontal and parietal bones were higher than those of the sagittal and coronal sutures (P<0.05), whereas the opposite ultimate strain findings were revealed (P<0.05). CONCLUSIONS: There was no significant difference in ultimate stress, elastic modulus, or ultimate strain between the sagittal and coronal sutures. However, there were significant differences in ultimate stress, elastic modulus, and ultimate strain between the frontal and parietal bones as well as between the cranial bones and sutures.

Open-access reader

About this research paper

What this paper is about

BACKGROUND: The mechanical properties of 1-2-year-old pediatric cranial bones and sutures and their influential factors were studied to better understand how the pediatric calvarium reacts to loading. MATERIAL AND METHODS: Cranial bone and suture specimens were extracted from seven fresh-frozen human infant cadavers (1.5±0.5 years old). Eight specimens were obtained from each subject: two frontal bones, two parietal bones, two sagittal suture samples, and two coronal suture samples. The specimens were tested in a three-point bend setup at 1.5 mm/s. The mechanical properties, such as ultimate stress, elastic modulus, and ultimate strain, were calculated for each specimen. RESULTS: The ultimate stress and elastic modulus of the frontal bone were higher than those of the parietal bone (P<0.05). No differences were found between the coronal and sagittal sutures in ultimate stress, elastic modulus, or ultimate strain (P>0.05). The ultimate stress and elastic modulus of the frontal and parietal bones were higher than those of the sagittal and coronal sutures (P<0.05), whereas the opposite ultimate strain findings were revealed (P<0.05). CONCLUSIONS: There was no significant difference in ultimate stress, elastic modulus, or ultimate strain between the sagittal and coronal sutures. However, there were significant differences in ultimate stress, elastic modulus, and ultimate strain between the frontal and parietal bones as well as between the cranial bones and sutures.

Why it matters

OpenAlex reports 41 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

BACKGROUND: The mechanical properties of 1-2-year-old pediatric cranial bones and sutures and their influential factors were studied to better understand how the pediatric calvarium reacts to loading. MATERIAL AND METHODS: Cranial bone and suture specimens were extracted from seven fresh-frozen human infant cadavers (1.5±0.5 years old). Eight specimens were obtained from each subject: two frontal bones, two parietal bones, two sagittal suture samples, and two coronal suture samples. The specimens were tested in a three-point bend setup at 1.5 mm/s. The mechanical properties, such as ultimate stress, elastic modulus, and ultimate strain, were calculated for each specimen. RESULTS: The ultimate stress and elastic modulus of the frontal bone were higher than those of the parietal bone (P<0.05). No differences were found between the coronal and sagittal sutures in ultimate stress, elastic modulus, or ultimate strain (P>0.05). The ultimate stress and elastic modulus of the frontal and parietal bones were higher than those of the sagittal and coronal sutures (P<0.05), whereas the opposite ultimate strain findings were revealed (P<0.05). CONCLUSIONS: There was no significant difference in ultimate stress, elastic modulus, or ultimate strain between the sagittal and coronal sutures. However, there were significant differences in ultimate stress, elastic modulus, and ultimate strain between the frontal and parietal bones as well as between the cranial bones and sutures.

Key concepts: Coronal plane, Coronal suture, Sagittal plane, Parietal bone, Sagittal suture, Frontal bone, Cadaver, Anatomy

Related papers

Back to paper searchBrowse research topicsOriginal source
Mechanical Properties of Cranial Bones and Sutures in 1–2-Year-Old Infants — Research Paper | ScholarLens