2012Polish Journal of MicrobiologyOpen access

Modifications Influencing Widal Test Reactivity in a Novel Microplate Assay

ADEL ALMOGREN, Zahid Shakoor, M Adám, Mohammad O. Gad-El-Rab, Hassan Abdulaziz Musa

Open full text 3 citations

Abstract

Reliability of the Widal tube agglutination test has been the subject of many controversies over the years. This study was performed to assess the effect of certain modifications on the performance of Widal test in a novel microplate assay. Sera from 37 patients (21 males; 16 females) (mean age 28 +/- 7 years) were tested in the Immunology Unit at King Khalid University Hospital, Riyadh. Among them were 26 patients with suspected typhoid fever and 11 had bacteriologically confirmed diagnosis of Salmonella infection. The modifications included either the use of 0.5% bovine serum albumin (BSA), absorption of sera with sheep red blood cells (SRBC) or heat inactivation of sera. Compared with Widal tube agglutination test, microplate assay with SRBC absorption of the sera from patients with suspected typhoid fever was not only associated with enhancement of detection titers for both H (p < or = 0.001) and O (p < or = 0.005) Salmonella agglutinins but also the percentage of reactivity. The presence of BSA augmented detection titers for Salmonella H agglutinins (p < or = 0.02) only. Heat inactivation of sera however was found to be associated with reduction in the detectable titers for both H (p < or = 0.03) and O (p < or = 0.01) agglutinins. Increased titers of Salmonella agglutinins were also evident in 11 patients with confirmed diagnosis of Salmonella infection. The novel microplate agglutination assay using the SRBC absorption was associated with enhancement in Widal test reactivity and appears to be a useful alternative for the diagnosis of Salmonella infection.

Open-access reader

About this research paper

What this paper is about

Reliability of the Widal tube agglutination test has been the subject of many controversies over the years. This study was performed to assess the effect of certain modifications on the performance of Widal test in a novel microplate assay. Sera from 37 patients (21 males; 16 females) (mean age 28 +/- 7 years) were tested in the Immunology Unit at King Khalid University Hospital, Riyadh. Among them were 26 patients with suspected typhoid fever and 11 had bacteriologically confirmed diagnosis of Salmonella infection. The modifications included either the use of 0.5% bovine serum albumin (BSA), absorption of sera with sheep red blood cells (SRBC) or heat inactivation of sera. Compared with Widal tube agglutination test, microplate assay with SRBC absorption of the sera from patients with suspected typhoid fever was not only associated with enhancement of detection titers for both H (p < or = 0.001) and O (p < or = 0.005) Salmonella agglutinins but also the percentage of reactivity. The presence of BSA augmented detection titers for Salmonella H agglutinins (p < or = 0.02) only. Heat inactivation of sera however was found to be associated with reduction in the detectable titers for both H (p < or = 0.03) and O (p < or = 0.01) agglutinins. Increased titers of Salmonella agglutinins were also evident in 11 patients with confirmed diagnosis of Salmonella infection. The novel microplate agglutination assay using the SRBC absorption was associated with enhancement in Widal test reactivity and appears to be a useful alternative for the diagnosis of Salmonella infection.

Why it matters

OpenAlex reports 3 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Reliability of the Widal tube agglutination test has been the subject of many controversies over the years. This study was performed to assess the effect of certain modifications on the performance of Widal test in a novel microplate assay. Sera from 37 patients (21 males; 16 females) (mean age 28 +/- 7 years) were tested in the Immunology Unit at King Khalid University Hospital, Riyadh. Among them were 26 patients with suspected typhoid fever and 11 had bacteriologically confirmed diagnosis of Salmonella infection. The modifications included either the use of 0.5% bovine serum albumin (BSA), absorption of sera with sheep red blood cells (SRBC) or heat inactivation of sera. Compared with Widal tube agglutination test, microplate assay with SRBC absorption of the sera from patients with suspected typhoid fever was not only associated with enhancement of detection titers for both H (p < or = 0.001) and O (p < or = 0.005) Salmonella agglutinins but also the percentage of reactivity. The presence of BSA augmented detection titers for Salmonella H agglutinins (p < or = 0.02) only. Heat inactivation of sera however was found to be associated with reduction in the detectable titers for both H (p < or = 0.03) and O (p < or = 0.01) agglutinins. Increased titers of Salmonella agglutinins were also evident in 11 patients with confirmed diagnosis of Salmonella infection. The novel microplate agglutination assay using the SRBC absorption was associated with enhancement in Widal test reactivity and appears to be a useful alternative for the diagnosis of Salmonella infection.

Key concepts: Typhoid fever, Widal test, Titer, Salmonella, Salmonella typhi, Agglutination (biology), Direct agglutination test, Medicine

Related papers

Back to paper searchBrowse research topicsOriginal source
Modifications Influencing Widal Test Reactivity in a Novel Microplate Assay — Research Paper | ScholarLens