2015EndoscopyRequires access

Electrohydraulic lithotripsy of large bile duct stones under direct cholangioscopy with a double-balloon endoscope

Ryunosuke Hakuta, Hirofumi Kogure, Hiroyuki Isayama, Atsuo Yamada, Tsuyoshi Hamada, Yousuke Nakai, Kazuhiko Koike

Open publisher page 12 citations

Abstract

The use of a short double-balloon endoscope facilitates the endoscopic removal of bile duct stones in patients with surgically altered anatomy [ 1 ] [ 2 ]. However, the narrow and long working channel of the double-balloon endoscope occasionally makes the procedure difficult and time-consuming. Herein, we present the case of a patient with a history of hepaticojejunostomy in whom large bile duct stones were successfully fragmented and removed under direct visualization with a short double-balloon endoscope and electrohydraulic lithotripsy (EHL). An 82-year-old woman with a history of hepaticojejunostomy and Roux-en-Y reconstruction for congenital biliary dilatation was admitted with cholangitis due to intrahepatic bile duct stones. Endoscopic retrograde cholangiopancreatography (ERCP) was carried out with a short double-balloon endoscope (EC-450BI5, 2.8-mm-wide and 152-cm-long working channel; Fujifilm Corp., Tokyo, Japan), and biliary access was readily obtained with a usual ERCP cannula and a 0.025-in guidewire. Cholangiography delineated an 18-mm filling defect in the right hepatic duct ([ Fig. 1 ], [ Fig. 2 a ]). Fig. 1 Cholangiography with a short double-balloon endoscope delineates large bile duct stones (arrow) in the right hepatic duct of an 82-year-old woman with a history of hepaticojejunostomy. Fig. 2 a Direct cholangioscopy with a double-balloon endoscope reveals large bile duct stones in the right hepatic duct. b Successful fragmentation of the bile duct stones with electrohydraulic lithotripsy. After attempts to extract the bile duct stones with a retrieval balloon and basket catheters had failed, EHL was performed with the AUTOLITH System and a 1.9-Fr, 250-cm-long probe (Northgate Technologies, Elgin, Illinois, USA). The distal end of the double-balloon endoscope was inserted into the bile duct, and water irrigation for EHL was achieved by pushing the balloon against the anastomosis and flushing saline through the channel. Large stones were successfully fragmented with EHL, followed by complete removal with a balloon catheter ([ Fig. 2 b ], [ Video 1 ]). No procedure-related complications were observed. Quality: mobile 360 480 720 Download Electrohydraulic lithotripsy combined with double-balloon endoscopy for large bile duct stones in a patient with a history of hepaticojejunostomy. This is the first report of successful stone fragmentation with EHL under direct visualization with a short double-balloon enteroscope. The effectiveness of EHL combined with a single-balloon endoscope has been reported [ 3 ], and given the potential superiority of a double-balloon enteroscope over a single-balloon enteroscope in terms of endoscope insertion [ 4 ], EHL with a double-balloon enteroscope can further increase the technical success rate of stone removal in patients with surgically altered anatomy. Endoscopy_UCTN_Code_TTT_1AR_2AH

About this research paper

What this paper is about

The use of a short double-balloon endoscope facilitates the endoscopic removal of bile duct stones in patients with surgically altered anatomy [ 1 ] [ 2 ]. However, the narrow and long working channel of the double-balloon endoscope occasionally makes the procedure difficult and time-consuming. Herein, we present the case of a patient with a history of hepaticojejunostomy in whom large bile duct stones were successfully fragmented and removed under direct visualization with a short double-balloon endoscope and electrohydraulic lithotripsy (EHL). An 82-year-old woman with a history of hepaticojejunostomy and Roux-en-Y reconstruction for congenital biliary dilatation was admitted with cholangitis due to intrahepatic bile duct stones. Endoscopic retrograde cholangiopancreatography (ERCP) was carried out with a short double-balloon endoscope (EC-450BI5, 2.8-mm-wide and 152-cm-long working channel; Fujifilm Corp., Tokyo, Japan), and biliary access was readily obtained with a usual ERCP cannula and a 0.025-in guidewire. Cholangiography delineated an 18-mm filling defect in the right hepatic duct ([ Fig. 1 ], [ Fig. 2 a ]). Fig. 1 Cholangiography with a short double-balloon endoscope delineates large bile duct stones (arrow) in the right hepatic duct of an 82-year-old woman with a history of hepaticojejunostomy. Fig. 2 a Direct cholangioscopy with a double-balloon endoscope reveals large bile duct stones in the right hepatic duct. b Successful fragmentation of the bile duct stones with electrohydraulic lithotripsy. After attempts to extract the bile duct stones with a retrieval balloon and basket catheters had failed, EHL was performed with the AUTOLITH System and a 1.9-Fr, 250-cm-long probe (Northgate Technologies, Elgin, Illinois, USA). The distal end of the double-balloon endoscope was inserted into the bile duct, and water irrigation for EHL was achieved by pushing the balloon against the anastomosis and flushing saline through the channel. Large stones were successfully fragmented with EHL, followed by complete removal with a balloon catheter ([ Fig. 2 b ], [ Video 1 ]). No procedure-related complications were observed. Quality: mobile 360 480 720 Download Electrohydraulic lithotripsy combined with double-balloon endoscopy for large bile duct stones in a patient with a history of hepaticojejunostomy. This is the first report of successful stone fragmentation with EHL under direct visualization with a short double-balloon enteroscope. The effectiveness of EHL combined with a single-balloon endoscope has been reported [ 3 ], and given the potential superiority of a double-balloon enteroscope over a single-balloon enteroscope in terms of endoscope insertion [ 4 ], EHL with a double-balloon enteroscope can further increase the technical success rate of stone removal in patients with surgically altered anatomy. Endoscopy_UCTN_Code_TTT_1AR_2AH

Why it matters

OpenAlex reports 12 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

The use of a short double-balloon endoscope facilitates the endoscopic removal of bile duct stones in patients with surgically altered anatomy [ 1 ] [ 2 ]. However, the narrow and long working channel of the double-balloon endoscope occasionally makes the procedure difficult and time-consuming. Herein, we present the case of a patient with a history of hepaticojejunostomy in whom large bile duct stones were successfully fragmented and removed under direct visualization with a short double-balloon endoscope and electrohydraulic lithotripsy (EHL). An 82-year-old woman with a history of hepaticojejunostomy and Roux-en-Y reconstruction for congenital biliary dilatation was admitted with cholangitis due to intrahepatic bile duct stones. Endoscopic retrograde cholangiopancreatography (ERCP) was carried out with a short double-balloon endoscope (EC-450BI5, 2.8-mm-wide and 152-cm-long working channel; Fujifilm Corp., Tokyo, Japan), and biliary access was readily obtained with a usual ERCP cannula and a 0.025-in guidewire. Cholangiography delineated an 18-mm filling defect in the right hepatic duct ([ Fig. 1 ], [ Fig. 2 a ]). Fig. 1 Cholangiography with a short double-balloon endoscope delineates large bile duct stones (arrow) in the right hepatic duct of an 82-year-old woman with a history of hepaticojejunostomy. Fig. 2 a Direct cholangioscopy with a double-balloon endoscope reveals large bile duct stones in the right hepatic duct. b Successful fragmentation of the bile duct stones with electrohydraulic lithotripsy. After attempts to extract the bile duct stones with a retrieval balloon and basket catheters had failed, EHL was performed with the AUTOLITH System and a 1.9-Fr, 250-cm-long probe (Northgate Technologies, Elgin, Illinois, USA). The distal end of the double-balloon endoscope was inserted into the bile duct, and water irrigation for EHL was achieved by pushing the balloon against the anastomosis and flushing saline through the channel. Large stones were successfully fragmented with EHL, followed by complete removal with a balloon catheter ([ Fig. 2 b ], [ Video 1 ]). No procedure-related complications were observed. Quality: mobile 360 480 720 Download Electrohydraulic lithotripsy combined with double-balloon endoscopy for large bile duct stones in a patient with a history of hepaticojejunostomy. This is the first report of successful stone fragmentation with EHL under direct visualization with a short double-balloon enteroscope. The effectiveness of EHL combined with a single-balloon endoscope has been reported [ 3 ], and given the potential superiority of a double-balloon enteroscope over a single-balloon enteroscope in terms of endoscope insertion [ 4 ], EHL with a double-balloon enteroscope can further increase the technical success rate of stone removal in patients with surgically altered anatomy. Endoscopy_UCTN_Code_TTT_1AR_2AH

Key concepts: Endoscope, Medicine, Balloon, Lithotripsy, Bile duct, Endoscopy, URETEROSCOPE, Surgery

Related papers

Back to paper searchBrowse research topicsOriginal source
Electrohydraulic lithotripsy of large bile duct stones under direct cholangioscopy with a double-balloon endoscope — Research Paper | ScholarLens