2012•EP EuropaceOpen access

Lead complications, device infections, and clinical outcomes in the first year after implantation of cardiac resynchronization therapy-defibrillator and cardiac resynchronization therapy-pacemaker

Andreas Schuchert, Carmine Muto, Themistoklis Maounis, Robert Frank, Eric Boulogne, Alexander Polauck, Luigi Padeletti, for the MASCOT study group

Open full text 67 citations

Abstract

AIMS: The decision to implant a cardiac resynchronization therapy (CRT) system with (defibrillator, CRT-D) or without (pacemaker, CRT-P) cardioverter defibrillator should weigh its benefits and risks. This study examined the (i) incidence of loss of capture and infectious complications and (ii) 1-year clinical outcomes of 402 CRT-D and CRT-P recipients enrolled in the MASCOT study. METHODS AND RESULTS: The indications for CRT-D or CRT-P were posed by the implanting physicians. All (i) losses of atrial and right and left ventricular capture, (ii) system-related infections, and (iii) clinical outcomes, including hospitalizations for worsening heart failure (HF) and deaths from all causes, were recorded up to 1 year of follow-up. Cardiac resynchronization therapy-defibrillator was implanted in 228 (57%) and CRT-P in 174 (43%) patients. The incidence of loss of capture was greater in CRT-D with 21 patients (9.2%) than in CRT-P with 6 patient (3.5%) recipients (P = 0.01), while the infection rates were 1.3% (3 patients) and 1.2% (2 patients), respectively (ns). In the CRT-D group, 42 of 228 patients (18.4%) died or were hospitalized for HF, compared with 38 of 174 patients (21.8%) in the CRT-P group (ns). In the CRT-D group, 23 patients (10.1%) were hospitalized for worsening HF and 20 (8.8%) patients died, vs. 22 (12.6%) and 19 (10.9%) patients, respectively, in the CRT-P group (ns for both comparisons). CONCLUSIONS: Cardiac resynchronization therapy-defibrillator was implanted in 57% of candidates for CRT. Within 1 year after device implant, the incidence of loss of capture at any lead was nearly three-fold greater among CRT-D than among CRT-P recipients. System-related infections were infrequent and clinical outcomes were similar in both groups.

Open-access reader

About this research paper

What this paper is about

AIMS: The decision to implant a cardiac resynchronization therapy (CRT) system with (defibrillator, CRT-D) or without (pacemaker, CRT-P) cardioverter defibrillator should weigh its benefits and risks. This study examined the (i) incidence of loss of capture and infectious complications and (ii) 1-year clinical outcomes of 402 CRT-D and CRT-P recipients enrolled in the MASCOT study. METHODS AND RESULTS: The indications for CRT-D or CRT-P were posed by the implanting physicians. All (i) losses of atrial and right and left ventricular capture, (ii) system-related infections, and (iii) clinical outcomes, including hospitalizations for worsening heart failure (HF) and deaths from all causes, were recorded up to 1 year of follow-up. Cardiac resynchronization therapy-defibrillator was implanted in 228 (57%) and CRT-P in 174 (43%) patients. The incidence of loss of capture was greater in CRT-D with 21 patients (9.2%) than in CRT-P with 6 patient (3.5%) recipients (P = 0.01), while the infection rates were 1.3% (3 patients) and 1.2% (2 patients), respectively (ns). In the CRT-D group, 42 of 228 patients (18.4%) died or were hospitalized for HF, compared with 38 of 174 patients (21.8%) in the CRT-P group (ns). In the CRT-D group, 23 patients (10.1%) were hospitalized for worsening HF and 20 (8.8%) patients died, vs. 22 (12.6%) and 19 (10.9%) patients, respectively, in the CRT-P group (ns for both comparisons). CONCLUSIONS: Cardiac resynchronization therapy-defibrillator was implanted in 57% of candidates for CRT. Within 1 year after device implant, the incidence of loss of capture at any lead was nearly three-fold greater among CRT-D than among CRT-P recipients. System-related infections were infrequent and clinical outcomes were similar in both groups.

Why it matters

OpenAlex reports 67 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

AIMS: The decision to implant a cardiac resynchronization therapy (CRT) system with (defibrillator, CRT-D) or without (pacemaker, CRT-P) cardioverter defibrillator should weigh its benefits and risks. This study examined the (i) incidence of loss of capture and infectious complications and (ii) 1-year clinical outcomes of 402 CRT-D and CRT-P recipients enrolled in the MASCOT study. METHODS AND RESULTS: The indications for CRT-D or CRT-P were posed by the implanting physicians. All (i) losses of atrial and right and left ventricular capture, (ii) system-related infections, and (iii) clinical outcomes, including hospitalizations for worsening heart failure (HF) and deaths from all causes, were recorded up to 1 year of follow-up. Cardiac resynchronization therapy-defibrillator was implanted in 228 (57%) and CRT-P in 174 (43%) patients. The incidence of loss of capture was greater in CRT-D with 21 patients (9.2%) than in CRT-P with 6 patient (3.5%) recipients (P = 0.01), while the infection rates were 1.3% (3 patients) and 1.2% (2 patients), respectively (ns). In the CRT-D group, 42 of 228 patients (18.4%) died or were hospitalized for HF, compared with 38 of 174 patients (21.8%) in the CRT-P group (ns). In the CRT-D group, 23 patients (10.1%) were hospitalized for worsening HF and 20 (8.8%) patients died, vs. 22 (12.6%) and 19 (10.9%) patients, respectively, in the CRT-P group (ns for both comparisons). CONCLUSIONS: Cardiac resynchronization therapy-defibrillator was implanted in 57% of candidates for CRT. Within 1 year after device implant, the incidence of loss of capture at any lead was nearly three-fold greater among CRT-D than among CRT-P recipients. System-related infections were infrequent and clinical outcomes were similar in both groups.

Key concepts: Cardiac resynchronization therapy, Medicine, Implantable cardioverter-defibrillator, Cardiology, Internal medicine, Implant, Artificial cardiac pacemaker, Incidence (geometry)

Related papers

Back to paper searchBrowse research topicsOriginal source
Lead complications, device infections, and clinical outcomes in the first year after implantation of cardiac resynchronization therapy-defibrillator and cardiac resynchronization therapy-pacemaker — Research Paper | ScholarLens