DESIGN OF THE HIGH BETA CRYOMODULE FOR THE HIE-ISOLDE UPGRADE AT CERN
Larry R. Williams, A. P. Bouzoud, N. Delruelle, Yann Leclercq, Matteo Pasini
Abstract
Open-access reader
Larry R. Williams, A. P. Bouzoud, N. Delruelle, Yann Leclercq, Matteo Pasini
Abstract
Open-access reader
The major upgrade of the energy and intensity of the existing ISOLDE and REX-ISOLDE facilities at CERN will require the replacement of most of the existing ISOLDE post-acceleration by a superconducting linac based on quarter-wave resonators. The first stage of this upgrade involves the design, construction, installation and commissioning of two high- cryomodules downstream of REX, the existing post-accelerator. Each cryomodule houses five high-beta superconducting cavities and one superconducting solenoid. As well as providing optimum conditions for physics, where the internal active components must remain aligned within tight tolerances, the cryomodules need to function under stringent vacuum and cryogenic conditions. To preserve the RF cavity performance their assembly and sub-system testing will need to be carried out using specifically designed tooling in an ISO class 5 (US Fed. class 100) clean-room. We present the determining factors constraining the design of the high-beta cryomodules together with the design choices that these factors have imposed.
OpenAlex reports 6 citations for this work. Citation counts describe recorded attention and do not establish research quality.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
The major upgrade of the energy and intensity of the existing ISOLDE and REX-ISOLDE facilities at CERN will require the replacement of most of the existing ISOLDE post-acceleration by a superconducting linac based on quarter-wave resonators. The first stage of this upgrade involves the design, construction, installation and commissioning of two high- cryomodules downstream of REX, the existing post-accelerator. Each cryomodule houses five high-beta superconducting cavities and one superconducting solenoid. As well as providing optimum conditions for physics, where the internal active components must remain aligned within tight tolerances, the cryomodules need to function under stringent vacuum and cryogenic conditions. To preserve the RF cavity performance their assembly and sub-system testing will need to be carried out using specifically designed tooling in an ISO class 5 (US Fed. class 100) clean-room. We present the determining factors constraining the design of the high-beta cryomodules together with the design choices that these factors have imposed.
Key concepts: Upgrade, Large Hadron Collider, Linear particle accelerator, Particle accelerator, Physics, Nuclear engineering, Engineering, Nuclear physics