2011•International Linear ColliderOpen access

DESIGN OF THE HIGH BETA CRYOMODULE FOR THE HIE-ISOLDE UPGRADE AT CERN

Larry R. Williams, A. P. Bouzoud, N. Delruelle, Yann Leclercq, Matteo Pasini

Open full text 6 citations

Abstract

The major upgrade of the energy and intensity of the existing ISOLDE and REX-ISOLDE facilities at CERN will require the replacement of most of the existing ISOLDE post-acceleration by a superconducting linac based on quarter-wave resonators. The first stage of this upgrade involves the design, construction, installation and commissioning of two high- cryomodules downstream of REX, the existing post-accelerator. Each cryomodule houses five high-beta superconducting cavities and one superconducting solenoid. As well as providing optimum conditions for physics, where the internal active components must remain aligned within tight tolerances, the cryomodules need to function under stringent vacuum and cryogenic conditions. To preserve the RF cavity performance their assembly and sub-system testing will need to be carried out using specifically designed tooling in an ISO class 5 (US Fed. class 100) clean-room. We present the determining factors constraining the design of the high-beta cryomodules together with the design choices that these factors have imposed.

Open-access reader

About this research paper

What this paper is about

The major upgrade of the energy and intensity of the existing ISOLDE and REX-ISOLDE facilities at CERN will require the replacement of most of the existing ISOLDE post-acceleration by a superconducting linac based on quarter-wave resonators. The first stage of this upgrade involves the design, construction, installation and commissioning of two high- cryomodules downstream of REX, the existing post-accelerator. Each cryomodule houses five high-beta superconducting cavities and one superconducting solenoid. As well as providing optimum conditions for physics, where the internal active components must remain aligned within tight tolerances, the cryomodules need to function under stringent vacuum and cryogenic conditions. To preserve the RF cavity performance their assembly and sub-system testing will need to be carried out using specifically designed tooling in an ISO class 5 (US Fed. class 100) clean-room. We present the determining factors constraining the design of the high-beta cryomodules together with the design choices that these factors have imposed.

Why it matters

OpenAlex reports 6 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

The major upgrade of the energy and intensity of the existing ISOLDE and REX-ISOLDE facilities at CERN will require the replacement of most of the existing ISOLDE post-acceleration by a superconducting linac based on quarter-wave resonators. The first stage of this upgrade involves the design, construction, installation and commissioning of two high- cryomodules downstream of REX, the existing post-accelerator. Each cryomodule houses five high-beta superconducting cavities and one superconducting solenoid. As well as providing optimum conditions for physics, where the internal active components must remain aligned within tight tolerances, the cryomodules need to function under stringent vacuum and cryogenic conditions. To preserve the RF cavity performance their assembly and sub-system testing will need to be carried out using specifically designed tooling in an ISO class 5 (US Fed. class 100) clean-room. We present the determining factors constraining the design of the high-beta cryomodules together with the design choices that these factors have imposed.

Key concepts: Upgrade, Large Hadron Collider, Linear particle accelerator, Particle accelerator, Physics, Nuclear engineering, Engineering, Nuclear physics

Related papers

Back to paper searchBrowse research topicsOriginal source
DESIGN OF THE HIGH BETA CRYOMODULE FOR THE HIE-ISOLDE UPGRADE AT CERN — Research Paper | ScholarLens