2012Journal of Human KineticsOpen access

Determination of Maximal Oxygen Uptake Using the Bruce or a Novel Athlete-Led Protocol in a Mixed Population

Michael J. Hamlin, Nick Draper, Gavin Blackwell, Jeremy Shearman, Nicholas E. Kimber

Open full text 60 citations

Abstract

Treadmill tests for maximal oxygen uptake (V̇O2max) have traditionally used set speed and incline increments regardless of participants training or exercise background. The aim of this study was to determine the validity of a novel athlete-led protocol for determining maximal aerobic fitness in adults. Twenty-nine participants (21 male, 8 female, age 29.8 ± 9.5 y, BMI 24.4 ± 3.1, mean ± SD) from a variety of exercise backgrounds were asked to complete two maximal treadmill running tests (using the standard Bruce or a novel athlete-led protocol [ALP]) to volitional failure in a counter-balanced randomised cross-over trial one week apart. We found no substantial difference in maximal oxygen uptake (47.0 ± 9.1 and 46.8 ± 10.7 ml·kg(-1)·min(-1), mean ± SD for the ALP and Bruce protocols respectively), evidenced by the Spearman correlation coefficient of 0.93 (90% confidence limits, 0.88-0.96). However, compared to the Bruce protocol, participants completing the ALP protocol attained a substantially higher maximal heart rate (ALP = 182.8 ± 10.5, Bruce = 179.7 ± 8.7 beats·min(-1)). Additionally, using the Bruce protocol took a longer period of time (23.2 ± 17.0 s) compared to the ALP protocol. It seems that using either treadmill protocol will give you similar maximal oxygen uptake results. We suggest the ALP protocol which is simpler, quicker and probably better at achieving maximal heart rates is a useful alternative to the traditional Bruce protocol.

Open-access reader

About this research paper

What this paper is about

Treadmill tests for maximal oxygen uptake (V̇O2max) have traditionally used set speed and incline increments regardless of participants training or exercise background. The aim of this study was to determine the validity of a novel athlete-led protocol for determining maximal aerobic fitness in adults. Twenty-nine participants (21 male, 8 female, age 29.8 ± 9.5 y, BMI 24.4 ± 3.1, mean ± SD) from a variety of exercise backgrounds were asked to complete two maximal treadmill running tests (using the standard Bruce or a novel athlete-led protocol [ALP]) to volitional failure in a counter-balanced randomised cross-over trial one week apart. We found no substantial difference in maximal oxygen uptake (47.0 ± 9.1 and 46.8 ± 10.7 ml·kg(-1)·min(-1), mean ± SD for the ALP and Bruce protocols respectively), evidenced by the Spearman correlation coefficient of 0.93 (90% confidence limits, 0.88-0.96). However, compared to the Bruce protocol, participants completing the ALP protocol attained a substantially higher maximal heart rate (ALP = 182.8 ± 10.5, Bruce = 179.7 ± 8.7 beats·min(-1)). Additionally, using the Bruce protocol took a longer period of time (23.2 ± 17.0 s) compared to the ALP protocol. It seems that using either treadmill protocol will give you similar maximal oxygen uptake results. We suggest the ALP protocol which is simpler, quicker and probably better at achieving maximal heart rates is a useful alternative to the traditional Bruce protocol.

Why it matters

OpenAlex reports 60 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Treadmill tests for maximal oxygen uptake (V̇O2max) have traditionally used set speed and incline increments regardless of participants training or exercise background. The aim of this study was to determine the validity of a novel athlete-led protocol for determining maximal aerobic fitness in adults. Twenty-nine participants (21 male, 8 female, age 29.8 ± 9.5 y, BMI 24.4 ± 3.1, mean ± SD) from a variety of exercise backgrounds were asked to complete two maximal treadmill running tests (using the standard Bruce or a novel athlete-led protocol [ALP]) to volitional failure in a counter-balanced randomised cross-over trial one week apart. We found no substantial difference in maximal oxygen uptake (47.0 ± 9.1 and 46.8 ± 10.7 ml·kg(-1)·min(-1), mean ± SD for the ALP and Bruce protocols respectively), evidenced by the Spearman correlation coefficient of 0.93 (90% confidence limits, 0.88-0.96). However, compared to the Bruce protocol, participants completing the ALP protocol attained a substantially higher maximal heart rate (ALP = 182.8 ± 10.5, Bruce = 179.7 ± 8.7 beats·min(-1)). Additionally, using the Bruce protocol took a longer period of time (23.2 ± 17.0 s) compared to the ALP protocol. It seems that using either treadmill protocol will give you similar maximal oxygen uptake results. We suggest the ALP protocol which is simpler, quicker and probably better at achieving maximal heart rates is a useful alternative to the traditional Bruce protocol.

Key concepts: Bruce protocol, VO2 max, Treadmill, Population, Medicine, Protocol (science), Heart rate, Aerobic exercise

Related papers

Back to paper searchBrowse research topicsOriginal source
Determination of Maximal Oxygen Uptake Using the Bruce or a Novel Athlete-Led Protocol in a Mixed Population — Research Paper | ScholarLens