1992Analytical LettersRequires access

Enhanced Fluorimetric Determination of Europium with Dibenzoylmethane and Diphenylguanidine by Terbium

Zhikun Si, Guiyun Zhu, Bin Zhang, Wei Jiang

Open publisher page 5 citations

Abstract

A study of the enhanced fluorescence intensity of Eu-dibenzoylmethane(DBM)-diphenylguanidine(DPG) by terbium was made. The excitation and emission wavelengths were 390 and 612 nm, respectively. The fluorescence intensity was a linear function of the concentration of europium in the range 5.0×10−10 −6.0×10−8 M. The detection limit was 5.0×10−11 M. The standard addition method was used for the determination of europium in rare earth oxides.

About this research paper

What this paper is about

A study of the enhanced fluorescence intensity of Eu-dibenzoylmethane(DBM)-diphenylguanidine(DPG) by terbium was made. The excitation and emission wavelengths were 390 and 612 nm, respectively. The fluorescence intensity was a linear function of the concentration of europium in the range 5.0×10−10 −6.0×10−8 M. The detection limit was 5.0×10−11 M. The standard addition method was used for the determination of europium in rare earth oxides.

Why it matters

OpenAlex reports 5 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

A study of the enhanced fluorescence intensity of Eu-dibenzoylmethane(DBM)-diphenylguanidine(DPG) by terbium was made. The excitation and emission wavelengths were 390 and 612 nm, respectively. The fluorescence intensity was a linear function of the concentration of europium in the range 5.0×10−10 −6.0×10−8 M. The detection limit was 5.0×10−11 M. The standard addition method was used for the determination of europium in rare earth oxides.

Key concepts: Dibenzoylmethane, Terbium, Europium, Chemistry, Fluorescence, Detection limit, Excitation wavelength, Analytical Chemistry (journal)

Related papers

Back to paper searchBrowse research topicsOriginal source
Enhanced Fluorimetric Determination of Europium with Dibenzoylmethane and Diphenylguanidine by Terbium — Research Paper | ScholarLens