1990Pharmacology & ToxicologyRequires access

Morphine and Oxycodone in the Management of Cancer Pain: Plasma Levels Determined by Chemical and Radioreceptor Assays

Eija Kalso, Anneli Vainio, Maori J. Mattila, Per H. Rosenberg, Timo Seppαlä

Open publisher page 97 citations

Abstract

Morphine and oxycodone were administered to ten patients suffering from severe cancer pain in a double-blind cross-over study. The patients titrated themselves pain-free, first intravenously, using a patient-controlled analgesia device, and then orally. Each titration phase lasted for 48 hours. Blood samples were drawn after 36 hr of each administration phase. The plasma levels of morphine, morphine-6- and morphine-3 glucoronides were determined with high performance liquid chromatography (HPLC), whereas the oxycodone samples were assayed with gas chromatography (GC). Twin samples were analyzed for plasma opioid activity with a radioreceptor assay (RRA) using 3H-dihydromorphine and 3H-naloxone as radioligands. Adequate analgesia was achieved with both morphine and oxycodone. About 30% more oxycodone was needed intravenously, whereas 25% less oxycodone than morphine was consumed orally. There was a good linear correlation between the morphine concentrations measured with HPLC and RRA. The mean morphine-6-glucuronide to morphine concentration ratio was 2.3 after intravenous and 4.6 after oral administration. Results from RRA indicate that oxycodone in vivo is a potent mu-agonist and that at least part of its analgesic action is mediated by active metabolites. In vitro morphine glucuronides enhanced morphine in displacing radioligands from the opioid receptors, thus suggesting their complex interactions in vivo.

About this research paper

What this paper is about

Morphine and oxycodone were administered to ten patients suffering from severe cancer pain in a double-blind cross-over study. The patients titrated themselves pain-free, first intravenously, using a patient-controlled analgesia device, and then orally. Each titration phase lasted for 48 hours. Blood samples were drawn after 36 hr of each administration phase. The plasma levels of morphine, morphine-6- and morphine-3 glucoronides were determined with high performance liquid chromatography (HPLC), whereas the oxycodone samples were assayed with gas chromatography (GC). Twin samples were analyzed for plasma opioid activity with a radioreceptor assay (RRA) using 3H-dihydromorphine and 3H-naloxone as radioligands. Adequate analgesia was achieved with both morphine and oxycodone. About 30% more oxycodone was needed intravenously, whereas 25% less oxycodone than morphine was consumed orally. There was a good linear correlation between the morphine concentrations measured with HPLC and RRA. The mean morphine-6-glucuronide to morphine concentration ratio was 2.3 after intravenous and 4.6 after oral administration. Results from RRA indicate that oxycodone in vivo is a potent mu-agonist and that at least part of its analgesic action is mediated by active metabolites. In vitro morphine glucuronides enhanced morphine in displacing radioligands from the opioid receptors, thus suggesting their complex interactions in vivo.

Why it matters

OpenAlex reports 97 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Morphine and oxycodone were administered to ten patients suffering from severe cancer pain in a double-blind cross-over study. The patients titrated themselves pain-free, first intravenously, using a patient-controlled analgesia device, and then orally. Each titration phase lasted for 48 hours. Blood samples were drawn after 36 hr of each administration phase. The plasma levels of morphine, morphine-6- and morphine-3 glucoronides were determined with high performance liquid chromatography (HPLC), whereas the oxycodone samples were assayed with gas chromatography (GC). Twin samples were analyzed for plasma opioid activity with a radioreceptor assay (RRA) using 3H-dihydromorphine and 3H-naloxone as radioligands. Adequate analgesia was achieved with both morphine and oxycodone. About 30% more oxycodone was needed intravenously, whereas 25% less oxycodone than morphine was consumed orally. There was a good linear correlation between the morphine concentrations measured with HPLC and RRA. The mean morphine-6-glucuronide to morphine concentration ratio was 2.3 after intravenous and 4.6 after oral administration. Results from RRA indicate that oxycodone in vivo is a potent mu-agonist and that at least part of its analgesic action is mediated by active metabolites. In vitro morphine glucuronides enhanced morphine in displacing radioligands from the opioid receptors, thus suggesting their complex interactions in vivo.

Key concepts: Morphine, Oxycodone, Oxymorphone, Opioid, Pharmacology, Chemistry, Analgesic, (+)-Naloxone

Related papers

Back to paper searchBrowse research topicsOriginal source
Morphine and Oxycodone in the Management of Cancer Pain: Plasma Levels Determined by Chemical and Radioreceptor Assays — Research Paper | ScholarLens