2002•Journal of Structural EngineeringRequires access

Local, Distortional, and Euler Buckling of Thin-Walled Columns

Benjamin W. Schafer

Open publisher page 407 citations

Abstract

Open cross-section, thin-walled, cold-formed steel columns have at least three competing buckling modes: local, distortional, and Euler (i.e., flexural or flexural-torsional) buckling. Closed-form prediction of the buckling stress in the local mode, including interaction of the connected elements, and the distortional mode, including consideration of the elastic and geometric stiffness at the web/flange juncture, are provided and shown to agree well with numerical methods. Numerical analyses and experiments indicate postbuckling capacity in the distortional mode is lower than in the local mode. Current North American design specifications for cold-formed steel columns ignore local buckling interaction and do not provide an explicit check for distortional buckling. Existing experiments on cold-formed channel, zed, and rack columns indicate inconsistency and systematic error in current design methods and provide validation for alternative methods. A new method is proposed for design that explicitly incorporates local, distortional and Euler buckling, does not require calculations of effective width and/or effective properties, gives reliable predictions devoid of systematic error, and provides a means to introduce rational analysis for elastic buckling prediction into the design of thin-walled columns.

About this research paper

What this paper is about

Open cross-section, thin-walled, cold-formed steel columns have at least three competing buckling modes: local, distortional, and Euler (i.e., flexural or flexural-torsional) buckling. Closed-form prediction of the buckling stress in the local mode, including interaction of the connected elements, and the distortional mode, including consideration of the elastic and geometric stiffness at the web/flange juncture, are provided and shown to agree well with numerical methods. Numerical analyses and experiments indicate postbuckling capacity in the distortional mode is lower than in the local mode. Current North American design specifications for cold-formed steel columns ignore local buckling interaction and do not provide an explicit check for distortional buckling. Existing experiments on cold-formed channel, zed, and rack columns indicate inconsistency and systematic error in current design methods and provide validation for alternative methods. A new method is proposed for design that explicitly incorporates local, distortional and Euler buckling, does not require calculations of effective width and/or effective properties, gives reliable predictions devoid of systematic error, and provides a means to introduce rational analysis for elastic buckling prediction into the design of thin-walled columns.

Why it matters

OpenAlex reports 407 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Open cross-section, thin-walled, cold-formed steel columns have at least three competing buckling modes: local, distortional, and Euler (i.e., flexural or flexural-torsional) buckling. Closed-form prediction of the buckling stress in the local mode, including interaction of the connected elements, and the distortional mode, including consideration of the elastic and geometric stiffness at the web/flange juncture, are provided and shown to agree well with numerical methods. Numerical analyses and experiments indicate postbuckling capacity in the distortional mode is lower than in the local mode. Current North American design specifications for cold-formed steel columns ignore local buckling interaction and do not provide an explicit check for distortional buckling. Existing experiments on cold-formed channel, zed, and rack columns indicate inconsistency and systematic error in current design methods and provide validation for alternative methods. A new method is proposed for design that explicitly incorporates local, distortional and Euler buckling, does not require calculations of effective width and/or effective properties, gives reliable predictions devoid of systematic error, and provides a means to introduce rational analysis for elastic buckling prediction into the design of thin-walled columns.

Key concepts: Buckling, Flange, Finite strip method, Structural engineering, Euler's formula, Mode (computer interface), Cold-formed steel, Stiffness

Related papers

Back to paper searchBrowse research topicsOriginal source
Local, Distortional, and Euler Buckling of Thin-Walled Columns — Research Paper | ScholarLens