2015The International Journal of PhysicsRequires access

Measurement of Radon Gas Concentrations in Tap Water for Baghdad Governorate by Using Nuclear Track Detector (CR-39)

Nada Fadhil Tawfiq, Hazim Louis Mansour, Mahmood Salim Karim

Open publisher page 11 citations

Abstract

In the present work, we have measured the radon gas concentrations in tap water samples for selected regions (some of them were measured for the first time as far as authors know) in Baghdad governorate by using alpha-emitters registrations which are emitted from radon gas in (CR-39) nuclear track detector. The results of measurements have shown that the highest average radon gas concentration in tap water samples was found in B16 (AL-Zafraniya) region, which was equal to (0.190±0.01 Bq/L), while the lowest average radon gas concentration was found in B20 (AL-Karada) region, which was equal to (0.073±0.01 Bq/L), with an average value of (0.135±0.03 Bq/L). The highest value of annual effective dose in tap water samples was found in B16 region, which was equal to (0.694 μSv/y), while the lowest value of annual effective dose was found in B20 region, which was equal t (0.267 μSv/y), with an average value of (0.493±0.12 μSv/y). The present results have shown that radon gas concentrations in tap water samples were less than the recommended value (11.1 Bq/L) given by (USEPA,2012). There for tap water in all the studied sites in Baghdad Governorate is safe as for as radon concentration is concerned.

About this research paper

What this paper is about

In the present work, we have measured the radon gas concentrations in tap water samples for selected regions (some of them were measured for the first time as far as authors know) in Baghdad governorate by using alpha-emitters registrations which are emitted from radon gas in (CR-39) nuclear track detector. The results of measurements have shown that the highest average radon gas concentration in tap water samples was found in B16 (AL-Zafraniya) region, which was equal to (0.190±0.01 Bq/L), while the lowest average radon gas concentration was found in B20 (AL-Karada) region, which was equal to (0.073±0.01 Bq/L), with an average value of (0.135±0.03 Bq/L). The highest value of annual effective dose in tap water samples was found in B16 region, which was equal to (0.694 μSv/y), while the lowest value of annual effective dose was found in B20 region, which was equal t (0.267 μSv/y), with an average value of (0.493±0.12 μSv/y). The present results have shown that radon gas concentrations in tap water samples were less than the recommended value (11.1 Bq/L) given by (USEPA,2012). There for tap water in all the studied sites in Baghdad Governorate is safe as for as radon concentration is concerned.

Why it matters

OpenAlex reports 11 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

In the present work, we have measured the radon gas concentrations in tap water samples for selected regions (some of them were measured for the first time as far as authors know) in Baghdad governorate by using alpha-emitters registrations which are emitted from radon gas in (CR-39) nuclear track detector. The results of measurements have shown that the highest average radon gas concentration in tap water samples was found in B16 (AL-Zafraniya) region, which was equal to (0.190±0.01 Bq/L), while the lowest average radon gas concentration was found in B20 (AL-Karada) region, which was equal to (0.073±0.01 Bq/L), with an average value of (0.135±0.03 Bq/L). The highest value of annual effective dose in tap water samples was found in B16 region, which was equal to (0.694 μSv/y), while the lowest value of annual effective dose was found in B20 region, which was equal t (0.267 μSv/y), with an average value of (0.493±0.12 μSv/y). The present results have shown that radon gas concentrations in tap water samples were less than the recommended value (11.1 Bq/L) given by (USEPA,2012). There for tap water in all the studied sites in Baghdad Governorate is safe as for as radon concentration is concerned.

Key concepts: Tap water, Radon, Nuclear track, Radon gas, CR-39, Environmental science, Effective dose (radiation), Water source

Related papers

Back to paper searchBrowse research topicsOriginal source
Measurement of Radon Gas Concentrations in Tap Water for Baghdad Governorate by Using Nuclear Track Detector (CR-39) — Research Paper | ScholarLens