Evaluation of rheumatic tricuspid valve stenosis by real-time three-dimensional echocardiography: Table 1
Ashraf Mohammed Anwar, M.L. Geleijnse, Osama I.I. Soliman, Jackie S. McGhie, Attila Nemes, Folkert J. ten Cate
Abstract
Ashraf Mohammed Anwar, M.L. Geleijnse, Osama I.I. Soliman, Jackie S. McGhie, Attila Nemes, Folkert J. ten Cate
Abstract
Rheumatic heart disease causes tricuspid valve stenosis in up to 8% of patients.1 Unfortunately, tricuspid valve stenosis is easily missed at clinical examination except in advanced cases when a high degree of clinical suspicion exists.2 Undetected and thus uncorrected tricuspid valve stenosis may lead to postoperative low cardiac output despite successful relief of left-sided valve disease and carries a high mortality and morbidity.3 Two-dimensional echocardiography (2DE) can detect thickened tricuspid valve leaflets and a reduced tricuspid valve orifice diameter, and continuous-wave Doppler allows estimation of the tricuspid transvalvular pressure gradient.4 However, in most patients, it is not possible to visualise all three tricuspid valve leaflets simultaneously with 2DE.5 Transthoracic real-time three-dimensional echocardiography (RT3DE) may be a valuable imaging modality for the examination of stenotic tricuspid valves because all leaflets can be seen simultaneously and studied from both atrial and ventricular aspects. This study aimed to apply RT3DE for tricuspid valve assessment in patients with rheumatic tricuspid valve stenosis. Five patients (mean (SD) age 33 (7) years, four men) with an established diagnosis of rheumatic tricuspid valve disease were examined by 2DE (Philips Sonos 7500 with S3 probe, Best, The Netherlands) and RT3DE (same system with X4 probe). These patients were compared with eight patients …
OpenAlex reports 22 citations for this work. Citation counts describe recorded attention and do not establish research quality.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
Rheumatic heart disease causes tricuspid valve stenosis in up to 8% of patients.1 Unfortunately, tricuspid valve stenosis is easily missed at clinical examination except in advanced cases when a high degree of clinical suspicion exists.2 Undetected and thus uncorrected tricuspid valve stenosis may lead to postoperative low cardiac output despite successful relief of left-sided valve disease and carries a high mortality and morbidity.3 Two-dimensional echocardiography (2DE) can detect thickened tricuspid valve leaflets and a reduced tricuspid valve orifice diameter, and continuous-wave Doppler allows estimation of the tricuspid transvalvular pressure gradient.4 However, in most patients, it is not possible to visualise all three tricuspid valve leaflets simultaneously with 2DE.5 Transthoracic real-time three-dimensional echocardiography (RT3DE) may be a valuable imaging modality for the examination of stenotic tricuspid valves because all leaflets can be seen simultaneously and studied from both atrial and ventricular aspects. This study aimed to apply RT3DE for tricuspid valve assessment in patients with rheumatic tricuspid valve stenosis. Five patients (mean (SD) age 33 (7) years, four men) with an established diagnosis of rheumatic tricuspid valve disease were examined by 2DE (Philips Sonos 7500 with S3 probe, Best, The Netherlands) and RT3DE (same system with X4 probe). These patients were compared with eight patients …
Key concepts: Medicine, Tricuspid stenosis, Tricuspid valve, Cardiology, Internal medicine, Stenosis, Doppler echocardiography, Heart disease