Separation and Determination of Ephedrine and Pseudoephedrine by Combination of Flow Injection with Capillary Electrophoresis
Hongli Chen, Xiaofeng Chen, Qiaosheng Pu, Zenan Hu, Zhengyang Zhao, Martin A Hooper
Abstract
Hongli Chen, Xiaofeng Chen, Qiaosheng Pu, Zenan Hu, Zhengyang Zhao, Martin A Hooper
Abstract
A simple, rapid, and accurate method for the separation and determination of ephedrine and pseudoephedrine using direct UV absorbance detection has been developed by the combination of flow injection with capillary electrophoresis for the first time. The buffer solution used is a 40 mM borate solution with the pH adjusted to 9.5 using a 2 M NaOH solution. The linear calibration range is 50 to 1000 microg/mL (r = 0.9996) for both analytes, and the recoveries are 91.2-108.2% for ephedrine and 92.6-107.3% for pseudoephedrine, respectively. The relative standard deviation of the peak area is 1.6% for ephedrine and 1.3% for pseudoephedrine (n = 6) at a concentration of 500 microg/mL, respectively. A series of samples is injected repeatedly without current interruption and subsequent rinsing, and the contents of these two alkaloids in three marketed drugs and the medical plant, Ephedra sinica, are determined with satisfactory results by this method.
OpenAlex reports 32 citations for this work. Citation counts describe recorded attention and do not establish research quality.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
A simple, rapid, and accurate method for the separation and determination of ephedrine and pseudoephedrine using direct UV absorbance detection has been developed by the combination of flow injection with capillary electrophoresis for the first time. The buffer solution used is a 40 mM borate solution with the pH adjusted to 9.5 using a 2 M NaOH solution. The linear calibration range is 50 to 1000 microg/mL (r = 0.9996) for both analytes, and the recoveries are 91.2-108.2% for ephedrine and 92.6-107.3% for pseudoephedrine, respectively. The relative standard deviation of the peak area is 1.6% for ephedrine and 1.3% for pseudoephedrine (n = 6) at a concentration of 500 microg/mL, respectively. A series of samples is injected repeatedly without current interruption and subsequent rinsing, and the contents of these two alkaloids in three marketed drugs and the medical plant, Ephedra sinica, are determined with satisfactory results by this method.
Key concepts: Pseudoephedrine, Chemistry, Ephedrine, Chromatography, Capillary electrophoresis, Absorbance, Analyte, Nasal decongestant