D-STATCOM With Positive-Sequence Admittance and Negative-Sequence Conductance to Mitigate Voltage Fluctuations in High-Level Penetration of Distributed-Generation Systems

Tzung‐Lin Lee, Shang-Hung Hu, Yu-Hung Chan

Open publisher page 217 citations

Abstract

Voltage fluctuations resulting from variable output power of renewable energy sources are strictly challenging power quality in distributed-generation systems. This paper presents a control method for distributed static synchronous compensator (D-STATCOM) to alleviate variation of both positive- and negative-sequence voltages. The D-STATCOM simultaneously operates as fundamental positive-sequence admittance and fundamental negative-sequence conductance to restore the positive-sequence voltage to the nominal value as well as reduce the negative-sequence voltage to an allowable level. Both admittance and conductance are dynamically tuned to improve voltage-regulation performances in response to load changes and power variation of renewable sources. A proportional-resonant current regulator with selectively harmonic compensation is realized to control the fundamental current of the D-STATCOM as well as reduce the harmonic current, which could be an advantage in practical applications due to high voltage distortion in low-voltage microgrids. Voltage-regulation performances are discussed for different D-STATCOM locations as well as different D-STATCOM currents. Computer simulations and laboratory tests validate effectiveness.

About this research paper

What this paper is about

Voltage fluctuations resulting from variable output power of renewable energy sources are strictly challenging power quality in distributed-generation systems. This paper presents a control method for distributed static synchronous compensator (D-STATCOM) to alleviate variation of both positive- and negative-sequence voltages. The D-STATCOM simultaneously operates as fundamental positive-sequence admittance and fundamental negative-sequence conductance to restore the positive-sequence voltage to the nominal value as well as reduce the negative-sequence voltage to an allowable level. Both admittance and conductance are dynamically tuned to improve voltage-regulation performances in response to load changes and power variation of renewable sources. A proportional-resonant current regulator with selectively harmonic compensation is realized to control the fundamental current of the D-STATCOM as well as reduce the harmonic current, which could be an advantage in practical applications due to high voltage distortion in low-voltage microgrids. Voltage-regulation performances are discussed for different D-STATCOM locations as well as different D-STATCOM currents. Computer simulations and laboratory tests validate effectiveness.

Why it matters

OpenAlex reports 217 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Voltage fluctuations resulting from variable output power of renewable energy sources are strictly challenging power quality in distributed-generation systems. This paper presents a control method for distributed static synchronous compensator (D-STATCOM) to alleviate variation of both positive- and negative-sequence voltages. The D-STATCOM simultaneously operates as fundamental positive-sequence admittance and fundamental negative-sequence conductance to restore the positive-sequence voltage to the nominal value as well as reduce the negative-sequence voltage to an allowable level. Both admittance and conductance are dynamically tuned to improve voltage-regulation performances in response to load changes and power variation of renewable sources. A proportional-resonant current regulator with selectively harmonic compensation is realized to control the fundamental current of the D-STATCOM as well as reduce the harmonic current, which could be an advantage in practical applications due to high voltage distortion in low-voltage microgrids. Voltage-regulation performances are discussed for different D-STATCOM locations as well as different D-STATCOM currents. Computer simulations and laboratory tests validate effectiveness.

Key concepts: Control theory (sociology), Voltage, Disturbance voltage, Admittance, Voltage regulation, Engineering, Total harmonic distortion, Negative impedance converter

Related papers

Back to paper searchBrowse research topicsOriginal source
D-STATCOM With Positive-Sequence Admittance and Negative-Sequence Conductance to Mitigate Voltage Fluctuations in High-Level Penetration of Distributed-Generation Systems — Research Paper | ScholarLens