2013Catheterization and Cardiovascular InterventionsRequires access

Use of regadenoson for measurement of fractional flow reserve

Aditya Prasad, Meena Zareh, Reece Doherty, Ambarish Gopal, Hita Vora, Keith Somma, Anilkumar Mehra, Leonardo Clavijo, Ray Matthews, David M. Shavelle

Open publisher page 30 citations

Abstract

OBJECTIVE: To compare the use of regadenoson to adenosine for measurement of fractional flow reserve (FFR). BACKGROUND: FFR is an accepted method to assess the functional significance of intermediate coronary artery stenoses and uses adenosine to induce maximal hyperemia. The use of the selective A2a receptor agonist regadenoson for FFR is not established. METHODS: Fifty-seven patients undergoing clinically indicated FFR assessment of intermediate coronary stenoses were included. For the initial assessment of FFR, hyperemia was achieved by a standard intravenous adenosine infusion (140 mcg/kg/min). After a washout period of 10 min, FFR was reassessed using regadenoson as a single 0.4 mg intravenous bolus. FFR measurements were recorded at baseline and following maximal hyperemia with both agents. RESULTS: Mean age was 57 ± 8 years and 47 were male. Sixty coronary lesions were evaluated and were located in the left anterior descending in 34, the left circumflex in 9, right coronary in 15, and left main coronary artery in 2. Mean ( ± SD) FFR following adenosine and regadenoson was 0.79 ( ± 0.09) and 0.79 (±0.09), respectively, P = NS. Time to FFR nadir was shorter with regadenoson compared to adenosine, 36.6 ± 24 versus 66 ± 0.19 sec, P < 0.0001, respectively. No patients experienced any significant side effects related to regadenoson. CONCLUSIONS: Regadenoson is a viable alternative to intravenous adenosine for achieving maximal hyperemia during FFR assessment. Compared to adenosine, regadenoson has a similar hemodynamic response, achieves more rapid hyperemia, is easier to use, and has an excellent side-effect profile.

About this research paper

What this paper is about

OBJECTIVE: To compare the use of regadenoson to adenosine for measurement of fractional flow reserve (FFR). BACKGROUND: FFR is an accepted method to assess the functional significance of intermediate coronary artery stenoses and uses adenosine to induce maximal hyperemia. The use of the selective A2a receptor agonist regadenoson for FFR is not established. METHODS: Fifty-seven patients undergoing clinically indicated FFR assessment of intermediate coronary stenoses were included. For the initial assessment of FFR, hyperemia was achieved by a standard intravenous adenosine infusion (140 mcg/kg/min). After a washout period of 10 min, FFR was reassessed using regadenoson as a single 0.4 mg intravenous bolus. FFR measurements were recorded at baseline and following maximal hyperemia with both agents. RESULTS: Mean age was 57 ± 8 years and 47 were male. Sixty coronary lesions were evaluated and were located in the left anterior descending in 34, the left circumflex in 9, right coronary in 15, and left main coronary artery in 2. Mean ( ± SD) FFR following adenosine and regadenoson was 0.79 ( ± 0.09) and 0.79 (±0.09), respectively, P = NS. Time to FFR nadir was shorter with regadenoson compared to adenosine, 36.6 ± 24 versus 66 ± 0.19 sec, P < 0.0001, respectively. No patients experienced any significant side effects related to regadenoson. CONCLUSIONS: Regadenoson is a viable alternative to intravenous adenosine for achieving maximal hyperemia during FFR assessment. Compared to adenosine, regadenoson has a similar hemodynamic response, achieves more rapid hyperemia, is easier to use, and has an excellent side-effect profile.

Why it matters

OpenAlex reports 30 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

OBJECTIVE: To compare the use of regadenoson to adenosine for measurement of fractional flow reserve (FFR). BACKGROUND: FFR is an accepted method to assess the functional significance of intermediate coronary artery stenoses and uses adenosine to induce maximal hyperemia. The use of the selective A2a receptor agonist regadenoson for FFR is not established. METHODS: Fifty-seven patients undergoing clinically indicated FFR assessment of intermediate coronary stenoses were included. For the initial assessment of FFR, hyperemia was achieved by a standard intravenous adenosine infusion (140 mcg/kg/min). After a washout period of 10 min, FFR was reassessed using regadenoson as a single 0.4 mg intravenous bolus. FFR measurements were recorded at baseline and following maximal hyperemia with both agents. RESULTS: Mean age was 57 ± 8 years and 47 were male. Sixty coronary lesions were evaluated and were located in the left anterior descending in 34, the left circumflex in 9, right coronary in 15, and left main coronary artery in 2. Mean ( ± SD) FFR following adenosine and regadenoson was 0.79 ( ± 0.09) and 0.79 (±0.09), respectively, P = NS. Time to FFR nadir was shorter with regadenoson compared to adenosine, 36.6 ± 24 versus 66 ± 0.19 sec, P < 0.0001, respectively. No patients experienced any significant side effects related to regadenoson. CONCLUSIONS: Regadenoson is a viable alternative to intravenous adenosine for achieving maximal hyperemia during FFR assessment. Compared to adenosine, regadenoson has a similar hemodynamic response, achieves more rapid hyperemia, is easier to use, and has an excellent side-effect profile.

Key concepts: Regadenoson, Fractional flow reserve, Medicine, Adenosine, Cardiology, Anesthesia, Internal medicine, Coronary artery disease

Related papers

Back to paper searchBrowse research topicsOriginal source
Use of regadenoson for measurement of fractional flow reserve — Research Paper | ScholarLens