2000IEEE Transactions on Applied SuperconductivityRequires access

Results on the superconducting magnet system for the Large Helical Device

T. Satow, S. Imagawa, N. Yanagi, K. Takahata, T. Mito, S. Yamada, H. Chikaraishi, A. Nishimura, Shuichi Satoh, O. Motojima

Open publisher page 17 citations

Abstract

The Large Helical Device (LHD) is a plasma physics experimental device with eight superconducting coils. Design and construction of LHD started in April 1990. The trial operation and the first plasma discharge of the eight-year Phase I project for LHD were finished on the last day of March 1998 as initially planned. The second experimental campaign and several excitation tests were conducted from August 1998 to January 1999. Major test results on the superconducting magnet system for LHD are as follows: (1) The cooldown time of the LHD coils and support structure was 23 days. The LHD cryogenic system succeeded in 6400-hour operation and proved its high reliability. (2) Although the inside coil lead and the inner block of one helical coil caused two-stage successive normal propagation at a helical current of 11.45 kA, they were energized to the same current in the superconducting state in the next excitation test. (3) All six poloidal coils were excited stably. (4) Nine flexible superconducting bus-lines with a total length of 497 m were operated stably and safely. In the third experimental campaign many plasma discharge tests up to a plasma field of 2.9 T were carried out.

About this research paper

What this paper is about

The Large Helical Device (LHD) is a plasma physics experimental device with eight superconducting coils. Design and construction of LHD started in April 1990. The trial operation and the first plasma discharge of the eight-year Phase I project for LHD were finished on the last day of March 1998 as initially planned. The second experimental campaign and several excitation tests were conducted from August 1998 to January 1999. Major test results on the superconducting magnet system for LHD are as follows: (1) The cooldown time of the LHD coils and support structure was 23 days. The LHD cryogenic system succeeded in 6400-hour operation and proved its high reliability. (2) Although the inside coil lead and the inner block of one helical coil caused two-stage successive normal propagation at a helical current of 11.45 kA, they were energized to the same current in the superconducting state in the next excitation test. (3) All six poloidal coils were excited stably. (4) Nine flexible superconducting bus-lines with a total length of 497 m were operated stably and safely. In the third experimental campaign many plasma discharge tests up to a plasma field of 2.9 T were carried out.

Why it matters

OpenAlex reports 17 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

The Large Helical Device (LHD) is a plasma physics experimental device with eight superconducting coils. Design and construction of LHD started in April 1990. The trial operation and the first plasma discharge of the eight-year Phase I project for LHD were finished on the last day of March 1998 as initially planned. The second experimental campaign and several excitation tests were conducted from August 1998 to January 1999. Major test results on the superconducting magnet system for LHD are as follows: (1) The cooldown time of the LHD coils and support structure was 23 days. The LHD cryogenic system succeeded in 6400-hour operation and proved its high reliability. (2) Although the inside coil lead and the inner block of one helical coil caused two-stage successive normal propagation at a helical current of 11.45 kA, they were energized to the same current in the superconducting state in the next excitation test. (3) All six poloidal coils were excited stably. (4) Nine flexible superconducting bus-lines with a total length of 497 m were operated stably and safely. In the third experimental campaign many plasma discharge tests up to a plasma field of 2.9 T were carried out.

Key concepts: Large Helical Device, Superconducting magnet, Electromagnetic coil, Magnet, Plasma, Superconductivity, Excitation, Superconducting Coils

Related papers

Back to paper searchBrowse research topicsOriginal source
Results on the superconducting magnet system for the Large Helical Device — Research Paper | ScholarLens