2006IEEE Transactions on Electron DevicesRequires access

Design and Field Emission Test of Carbon Nanotube Pasted Cathodes for Traveling-Wave Tube Applications

H.J. Kim, J.J. Choi, Jong Hun Han, J.H. Park, Ji‐Beom Yoo

Open publisher page 54 citations

Abstract

This paper presents results of computational and experimental studies of carbon nanotube (CNT) cathodes in gridded focusing guns intended for traveling-wave tube applications. With a curved CNT cathode, a cold beam emission of 11 mA was observed in a diode configuration. Two gridded focusing cathodes pasted with CNTs were then fabricated. When the applied cathode voltage was -0.86 kV, both grid and anode were at ground potential, and the cathode-to-grid distance was 200 mum, the dc emission current from the first gridded CNT cathode was measured to be 4.2 mA. The triode field emission characteristics with two accelerating stages in pulse operation were also examined. With the cathode voltage at -4 kV, a cathode-grid potential difference of 1.38 kV, and a pulsewidth of 20 mus, the measured pulsed current emission was 4.6 mA. The measured current was found to agree with MAGIC2D simulation results. Furthermore, by configuring a double-gridded focusing gun, a significant improvement in the beam focusing data collected through computer modeling was seen

About this research paper

What this paper is about

This paper presents results of computational and experimental studies of carbon nanotube (CNT) cathodes in gridded focusing guns intended for traveling-wave tube applications. With a curved CNT cathode, a cold beam emission of 11 mA was observed in a diode configuration. Two gridded focusing cathodes pasted with CNTs were then fabricated. When the applied cathode voltage was -0.86 kV, both grid and anode were at ground potential, and the cathode-to-grid distance was 200 mum, the dc emission current from the first gridded CNT cathode was measured to be 4.2 mA. The triode field emission characteristics with two accelerating stages in pulse operation were also examined. With the cathode voltage at -4 kV, a cathode-grid potential difference of 1.38 kV, and a pulsewidth of 20 mus, the measured pulsed current emission was 4.6 mA. The measured current was found to agree with MAGIC2D simulation results. Furthermore, by configuring a double-gridded focusing gun, a significant improvement in the beam focusing data collected through computer modeling was seen

Why it matters

OpenAlex reports 54 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

This paper presents results of computational and experimental studies of carbon nanotube (CNT) cathodes in gridded focusing guns intended for traveling-wave tube applications. With a curved CNT cathode, a cold beam emission of 11 mA was observed in a diode configuration. Two gridded focusing cathodes pasted with CNTs were then fabricated. When the applied cathode voltage was -0.86 kV, both grid and anode were at ground potential, and the cathode-to-grid distance was 200 mum, the dc emission current from the first gridded CNT cathode was measured to be 4.2 mA. The triode field emission characteristics with two accelerating stages in pulse operation were also examined. With the cathode voltage at -4 kV, a cathode-grid potential difference of 1.38 kV, and a pulsewidth of 20 mus, the measured pulsed current emission was 4.6 mA. The measured current was found to agree with MAGIC2D simulation results. Furthermore, by configuring a double-gridded focusing gun, a significant improvement in the beam focusing data collected through computer modeling was seen

Key concepts: Triode, Cathode, Field electron emission, Carbon nanotube, Materials science, Anode, Traveling-wave tube, Diode

Related papers

Back to paper searchBrowse research topicsOriginal source
Design and Field Emission Test of Carbon Nanotube Pasted Cathodes for Traveling-Wave Tube Applications — Research Paper | ScholarLens