Laryngeal Ultrasonography Versus Cuff Leak Test in Predicting Postextubation Stridor
Haleh Mikaeili, Mohammad Yazdchi, Mohammad Kazem Tarzamni, Khalil Ansarin, Ghasemzadeh, Maryam
Abstract
Haleh Mikaeili, Mohammad Yazdchi, Mohammad Kazem Tarzamni, Khalil Ansarin, Ghasemzadeh, Maryam
Abstract
INTRODUCTION: Although cuff leak test has been proposed as a simple method of predicting the occurrence of postextubation stridor, cut-off point of cuff-leak volume substantially differs between previous studies. In addition, laryngeal ultrasonography including measurement of air column width could predict postextubation stridor. The aim of the present study was to evaluate the value of laryngeal ultrasonography versus cuff leak test in predicting postextubation stridor. METHODS: In a prospective study, all patients intubated for a minimum of 24 h for acute respiratory failure, airway protection and other causes were included. Patients were evaluated for postextubation stridor and need for reintubation after extubation. The cuff leak volume was defined as a difference between expiratory tidal volumes with the cuff inflated and deflated. Laryngeal air column width was defined as the width of air passed through the vocal cords as determined by laryngeal ultrasonography. The air-column width difference was the width difference between balloon-cuff inflation and deflation. RESULTS: Forty one intubated patients with the mean age of 57.16±20.07 years were included. Postextubation stridor was observed in 4 patients (9.75%). Cuff leak test (cut off point: 249 mL) showed sensitivity and specificity of 75% and 59%, respectively. In addition, laryngeal ultrasonography (cut off point for air column width: 10.95 mm) resulted in sensitivity and specificity of 50% and 54%, respectively. Positive predictive value of both methods were <20%. CONCLUSION: Both cuff leak test and laryngeal ultrasonography have low positive predictive value and sensitivity in predicting postextubation stridor and should be used with caution in this regard.
OpenAlex reports 35 citations for this work. Citation counts describe recorded attention and do not establish research quality.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
INTRODUCTION: Although cuff leak test has been proposed as a simple method of predicting the occurrence of postextubation stridor, cut-off point of cuff-leak volume substantially differs between previous studies. In addition, laryngeal ultrasonography including measurement of air column width could predict postextubation stridor. The aim of the present study was to evaluate the value of laryngeal ultrasonography versus cuff leak test in predicting postextubation stridor. METHODS: In a prospective study, all patients intubated for a minimum of 24 h for acute respiratory failure, airway protection and other causes were included. Patients were evaluated for postextubation stridor and need for reintubation after extubation. The cuff leak volume was defined as a difference between expiratory tidal volumes with the cuff inflated and deflated. Laryngeal air column width was defined as the width of air passed through the vocal cords as determined by laryngeal ultrasonography. The air-column width difference was the width difference between balloon-cuff inflation and deflation. RESULTS: Forty one intubated patients with the mean age of 57.16±20.07 years were included. Postextubation stridor was observed in 4 patients (9.75%). Cuff leak test (cut off point: 249 mL) showed sensitivity and specificity of 75% and 59%, respectively. In addition, laryngeal ultrasonography (cut off point for air column width: 10.95 mm) resulted in sensitivity and specificity of 50% and 54%, respectively. Positive predictive value of both methods were <20%. CONCLUSION: Both cuff leak test and laryngeal ultrasonography have low positive predictive value and sensitivity in predicting postextubation stridor and should be used with caution in this regard.
Key concepts: Stridor, Medicine, Leak, Cuff, Airway, Ultrasonography, Anesthesia, Surgery