Monitoring and Risk Assessment of Pesticide Residues in Commercially Dried Vegetables
Young-Ho Seo, Tae‐Hee Cho, Chae-Kyu Hong, Mi-Sun Kim, Sung-Ja Cho, Won-Hee Park, In-Sook Hwang, Moo‐Sang Kim
Abstract
Young-Ho Seo, Tae‐Hee Cho, Chae-Kyu Hong, Mi-Sun Kim, Sung-Ja Cho, Won-Hee Park, In-Sook Hwang, Moo‐Sang Kim
Abstract
We tested for residual pesticide levels in dried vegetables in Seoul, Korea. A total of 100 samples of 13 different types of agricultural products were analyzed by a gas chromatography-nitrogen phosphate detector (GC-NPD), an electron capture detector (GC-μECD), a mass spectrometry detector (GC-MSD), and a high performance liquid chromatography-ultraviolet detector (HPLC-UV). We used multi-analysis methods to analyze for 253 different pesticide types. Among the selected agricultural products, residual pesticides were detected in 11 samples, of which 2 samples (2.0%) exceeded the Korea Maximum Residue limits (MRLs). We detected pesticide residue in 6 of 9 analyzed dried pepper leaves and 1 sample exceeded the Korea MRLs. Data obtained were then used for estimating the potential health risks associated with the exposures to these pesticides. The estimated daily intakes (EDIs) range from 0.1% of the acceptable daily intake (ADI) for bifenthrin to 8.4% of the ADI for cadusafos. The most critical commodity is cadusafos in chwinamul, contributing 8.4% to the hazard index (HI). This results show that the detected pesticides could not be considered a serious public health problem. Nevertheless, an investigation into continuous monitoring is recommended.
OpenAlex reports 35 citations for this work. Citation counts describe recorded attention and do not establish research quality.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
We tested for residual pesticide levels in dried vegetables in Seoul, Korea. A total of 100 samples of 13 different types of agricultural products were analyzed by a gas chromatography-nitrogen phosphate detector (GC-NPD), an electron capture detector (GC-μECD), a mass spectrometry detector (GC-MSD), and a high performance liquid chromatography-ultraviolet detector (HPLC-UV). We used multi-analysis methods to analyze for 253 different pesticide types. Among the selected agricultural products, residual pesticides were detected in 11 samples, of which 2 samples (2.0%) exceeded the Korea Maximum Residue limits (MRLs). We detected pesticide residue in 6 of 9 analyzed dried pepper leaves and 1 sample exceeded the Korea MRLs. Data obtained were then used for estimating the potential health risks associated with the exposures to these pesticides. The estimated daily intakes (EDIs) range from 0.1% of the acceptable daily intake (ADI) for bifenthrin to 8.4% of the ADI for cadusafos. The most critical commodity is cadusafos in chwinamul, contributing 8.4% to the hazard index (HI). This results show that the detected pesticides could not be considered a serious public health problem. Nevertheless, an investigation into continuous monitoring is recommended.
Key concepts: Pesticide, Pesticide residue, Bifenthrin, Chemistry, Gas chromatography, Chromatography, Toxicology, Environmental chemistry