Ampacity Derating Factors for Cables Buried in Short Segments of Conduit
P. Vaucheret, Rick Hartlein, William Z. Black
Abstract
P. Vaucheret, Rick Hartlein, William Z. Black
Abstract
Buried cables are often routed through short segments of conduit, and when this situation occurs, the ampacity must be reduced or the cable will overheat as a result of the high thermal resistance created at the location of the conduit. This problem is examined for extruded cables by using a finite element heat transfer software program to determine the derating in ampacity that cables in conduits must experience in order to remain below a maximum conductor temperature. The derating factors are provided as a function of conduit length, soil resistivity, burial depth and number of cables in the conduit. The results show that once the length of conduit exceeds about 20 times its outer diameter, then the ampacity of the circuit must be reduced to the value that it would have if the entire length were buried in the conduit. Factors that result in lower cable ampacities, such as high soil thermal resistivity and deeper burial depths lead to larger derating factors.
OpenAlex reports 37 citations for this work. Citation counts describe recorded attention and do not establish research quality.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
Buried cables are often routed through short segments of conduit, and when this situation occurs, the ampacity must be reduced or the cable will overheat as a result of the high thermal resistance created at the location of the conduit. This problem is examined for extruded cables by using a finite element heat transfer software program to determine the derating in ampacity that cables in conduits must experience in order to remain below a maximum conductor temperature. The derating factors are provided as a function of conduit length, soil resistivity, burial depth and number of cables in the conduit. The results show that once the length of conduit exceeds about 20 times its outer diameter, then the ampacity of the circuit must be reduced to the value that it would have if the entire length were buried in the conduit. Factors that result in lower cable ampacities, such as high soil thermal resistivity and deeper burial depths lead to larger derating factors.
Key concepts: Ampacity, Derating, Electrical conduit, Electrical conductor, Conductor, Engineering, Geology, Electrical engineering