1997•The AnalystRequires access

Optosensor for Cinchona Alkaloids With C18 Silica Gel as a Substrate

Zhilong Gong, Zhujun Zhang, Xiaofeng Yang

Open publisher page 13 citations

Abstract

A flow-through optosensor for cinchona alkaloids with C18 silica gel as a substrate is proposed. The sensor is developed in conjunction with a flow-injection analysis system and is based on the retention of the cinchona alkaloids on a C18 column and the enhancement of their fluorescence. The analytical performance characteristics of the proposed sensor for the detection and quantification of these alkaloids were as follows: the detection limits of quinine, cinchonine, quinidine and cinchonidine were 2.3, 31.6, 2.3 and 31.6 ng ml-1, respectively, with relative standard deviations of 0.9% for quinine and quinidine (20 ng ml-1, n = 7) and 1.1% for cinchonine and cinchonidine (4.0 micrograms ml-1, n =7), respectively. Most of the common species did not interfere. The recommended method has been successfully tested for determination of quinine in pharmaceutical preparations and soft drinks.

About this research paper

What this paper is about

A flow-through optosensor for cinchona alkaloids with C18 silica gel as a substrate is proposed. The sensor is developed in conjunction with a flow-injection analysis system and is based on the retention of the cinchona alkaloids on a C18 column and the enhancement of their fluorescence. The analytical performance characteristics of the proposed sensor for the detection and quantification of these alkaloids were as follows: the detection limits of quinine, cinchonine, quinidine and cinchonidine were 2.3, 31.6, 2.3 and 31.6 ng ml-1, respectively, with relative standard deviations of 0.9% for quinine and quinidine (20 ng ml-1, n = 7) and 1.1% for cinchonine and cinchonidine (4.0 micrograms ml-1, n =7), respectively. Most of the common species did not interfere. The recommended method has been successfully tested for determination of quinine in pharmaceutical preparations and soft drinks.

Why it matters

OpenAlex reports 13 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

A flow-through optosensor for cinchona alkaloids with C18 silica gel as a substrate is proposed. The sensor is developed in conjunction with a flow-injection analysis system and is based on the retention of the cinchona alkaloids on a C18 column and the enhancement of their fluorescence. The analytical performance characteristics of the proposed sensor for the detection and quantification of these alkaloids were as follows: the detection limits of quinine, cinchonine, quinidine and cinchonidine were 2.3, 31.6, 2.3 and 31.6 ng ml-1, respectively, with relative standard deviations of 0.9% for quinine and quinidine (20 ng ml-1, n = 7) and 1.1% for cinchonine and cinchonidine (4.0 micrograms ml-1, n =7), respectively. Most of the common species did not interfere. The recommended method has been successfully tested for determination of quinine in pharmaceutical preparations and soft drinks.

Key concepts: Cinchona Alkaloids, Substrate (aquarium), Cinchona, Chemistry, Silica gel, Chromatography, Organic chemistry, Catalysis

Related papers

Back to paper searchBrowse research topicsOriginal source
Optosensor for Cinchona Alkaloids With C18 Silica Gel as a Substrate — Research Paper | ScholarLens