1975AnesthesiologyRequires access

Lung Volumes and Closing Capacity with Continuous Positive Airway Pressure

Nabil Abboud, Kai Rehder, J. R. Rodarte, Robert E. Hyatt

Open publisher page 22 citations

Abstract

Total lung capacity, vital capacity, residual volume, and functional residual capacity were determined by body plethysmography and the single-breath oxygen (SBO2) test was performed at 0, 5, and 11 cm H20 continuous positive airway pressure in healthy, awake, seated, spontaneously breathing subjects. Mean values for the absolute lung volume at which phase IV of the SBO2 test begins (closing capacity) did not change significantly with continous positive airway pressure at 5 or 11 cm H2O. Mean total lung capacity, functional residual capacity, and residual volume increased significantly, and the mean closing volume, the lung volume above residual volume at which phase IV begins, decreased significantly with 11 cm H20 continuous positive airway pressure; differences at 5 cm H20 were not significant. The slope of the alveolar nitrogen plateau (phase III) obtained during the SBO-2 test did not change with continuous positive airway pressure.

About this research paper

What this paper is about

Total lung capacity, vital capacity, residual volume, and functional residual capacity were determined by body plethysmography and the single-breath oxygen (SBO2) test was performed at 0, 5, and 11 cm H20 continuous positive airway pressure in healthy, awake, seated, spontaneously breathing subjects. Mean values for the absolute lung volume at which phase IV of the SBO2 test begins (closing capacity) did not change significantly with continous positive airway pressure at 5 or 11 cm H2O. Mean total lung capacity, functional residual capacity, and residual volume increased significantly, and the mean closing volume, the lung volume above residual volume at which phase IV begins, decreased significantly with 11 cm H20 continuous positive airway pressure; differences at 5 cm H20 were not significant. The slope of the alveolar nitrogen plateau (phase III) obtained during the SBO-2 test did not change with continuous positive airway pressure.

Why it matters

OpenAlex reports 22 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Total lung capacity, vital capacity, residual volume, and functional residual capacity were determined by body plethysmography and the single-breath oxygen (SBO2) test was performed at 0, 5, and 11 cm H20 continuous positive airway pressure in healthy, awake, seated, spontaneously breathing subjects. Mean values for the absolute lung volume at which phase IV of the SBO2 test begins (closing capacity) did not change significantly with continous positive airway pressure at 5 or 11 cm H2O. Mean total lung capacity, functional residual capacity, and residual volume increased significantly, and the mean closing volume, the lung volume above residual volume at which phase IV begins, decreased significantly with 11 cm H20 continuous positive airway pressure; differences at 5 cm H20 were not significant. The slope of the alveolar nitrogen plateau (phase III) obtained during the SBO-2 test did not change with continuous positive airway pressure.

Key concepts: Functional residual capacity, Lung volumes, Medicine, Plethysmograph, Residual volume, Airway, Anesthesia, Lung

Related papers

Back to paper searchBrowse research topicsOriginal source
Lung Volumes and Closing Capacity with Continuous Positive Airway Pressure — Research Paper | ScholarLens