2013International Journal of Energy ResearchOpen access

Exergy analysis of single-stage and multi stage thermoelectric cooler

Sudhanshu Sharma, Vijay Kumar Dwivedi, Srabanti Pandit

Open full text 53 citations

Abstract

Thermoelectric devices are solid-state devices. Semiconductor thermoelectric cooling, based on the Peltier effect, has interesting capabilities compared to conventional cooling systems. In this work second law analysis of thermoelectric coolers has been done with the help of exergy destruction. In the first part, performance of single-stage thermoelectric coolers and multi stage thermoelectric coolers has been compared for same number of thermoelectric elements i.e. 50. The performance parameters considered to compare their performance are rate of refrigeration, coefficient of performance, second law efficiency and exergy destruction. In second part, multi stage thermoelectric coolers have been analyzed for three different combinations of number of elements in two stages of thermoelectric coolers. The result of the analysis shows that the performance of a multi stage thermoelectric cooler which has total 50 elements gives best performance when it has 30 elements in hotter side and 20 elements in colder side out of the three cases considered. The comparison of single-stage thermoelectric cooler and multistage thermoelectric cooler shows that for same number of elements rate of refrigeration (ROR) of single-stage thermoelectric cooler is much higher than that of multi stage thermoelectric cooler. The COP remains same for both of them but the peak value of cop is obtained at much lower value of current supplied in multi stage thermoelectric cooler. Exergy destruction has constant values in single stage as well as multi stage thermoelectric cooler when the two stages have equal number of elements but it decreases with increase in x. The result of comparison of multistage thermoelectric cooler for three values of x i.e. 0.5, 1, 1.5 shows that the COP, ROR and second law efficiency improve and exergy destruction degrades with increase in x and the best performance has been obtained for x = 1.5 out of the three values considered. Copyright © 2013 John Wiley & Sons, Ltd.

Open-access reader

About this research paper

What this paper is about

Thermoelectric devices are solid-state devices. Semiconductor thermoelectric cooling, based on the Peltier effect, has interesting capabilities compared to conventional cooling systems. In this work second law analysis of thermoelectric coolers has been done with the help of exergy destruction. In the first part, performance of single-stage thermoelectric coolers and multi stage thermoelectric coolers has been compared for same number of thermoelectric elements i.e. 50. The performance parameters considered to compare their performance are rate of refrigeration, coefficient of performance, second law efficiency and exergy destruction. In second part, multi stage thermoelectric coolers have been analyzed for three different combinations of number of elements in two stages of thermoelectric coolers. The result of the analysis shows that the performance of a multi stage thermoelectric cooler which has total 50 elements gives best performance when it has 30 elements in hotter side and 20 elements in colder side out of the three cases considered. The comparison of single-stage thermoelectric cooler and multistage thermoelectric cooler shows that for same number of elements rate of refrigeration (ROR) of single-stage thermoelectric cooler is much higher than that of multi stage thermoelectric cooler. The COP remains same for both of them but the peak value of cop is obtained at much lower value of current supplied in multi stage thermoelectric cooler. Exergy destruction has constant values in single stage as well as multi stage thermoelectric cooler when the two stages have equal number of elements but it decreases with increase in x. The result of comparison of multistage thermoelectric cooler for three values of x i.e. 0.5, 1, 1.5 shows that the COP, ROR and second law efficiency improve and exergy destruction degrades with increase in x and the best performance has been obtained for x = 1.5 out of the three values considered. Copyright © 2013 John Wiley & Sons, Ltd.

Why it matters

OpenAlex reports 53 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Thermoelectric devices are solid-state devices. Semiconductor thermoelectric cooling, based on the Peltier effect, has interesting capabilities compared to conventional cooling systems. In this work second law analysis of thermoelectric coolers has been done with the help of exergy destruction. In the first part, performance of single-stage thermoelectric coolers and multi stage thermoelectric coolers has been compared for same number of thermoelectric elements i.e. 50. The performance parameters considered to compare their performance are rate of refrigeration, coefficient of performance, second law efficiency and exergy destruction. In second part, multi stage thermoelectric coolers have been analyzed for three different combinations of number of elements in two stages of thermoelectric coolers. The result of the analysis shows that the performance of a multi stage thermoelectric cooler which has total 50 elements gives best performance when it has 30 elements in hotter side and 20 elements in colder side out of the three cases considered. The comparison of single-stage thermoelectric cooler and multistage thermoelectric cooler shows that for same number of elements rate of refrigeration (ROR) of single-stage thermoelectric cooler is much higher than that of multi stage thermoelectric cooler. The COP remains same for both of them but the peak value of cop is obtained at much lower value of current supplied in multi stage thermoelectric cooler. Exergy destruction has constant values in single stage as well as multi stage thermoelectric cooler when the two stages have equal number of elements but it decreases with increase in x. The result of comparison of multistage thermoelectric cooler for three values of x i.e. 0.5, 1, 1.5 shows that the COP, ROR and second law efficiency improve and exergy destruction degrades with increase in x and the best performance has been obtained for x = 1.5 out of the three values considered. Copyright © 2013 John Wiley & Sons, Ltd.

Key concepts: Thermoelectric cooling, Thermoelectric effect, Exergy, Coefficient of performance, Thermoelectric generator, Refrigeration, Thermoelectric materials, Materials science

Related papers

Back to paper searchBrowse research topicsOriginal source
Exergy analysis of single-stage and multi stage thermoelectric cooler — Research Paper | ScholarLens