1989The AnalystRequires access

Spectrophotometric determination of dissolved organic phosphorus in natural waters using in-line photo-oxidation and flow injection

Ian D. McKelvie, Barry T. Hart, Terence J. Cardwell, Robert W. Cattrall

Open publisher page 65 citations

Abstract

A rapid in-line photochemical digestion for use with flow injection (Fl) to determine the dissolved organic phosphorus (DOP) in natural waters is described. The Fl system includes a simple ultraviolet (UV) photoreactor and uses the tin(II) chloride reduction of phosphomolybdate for the spectrophotometric determination of the dissolved reactive phosphorus (DRP) produced by the photo-oxidation. Samples in the range 0.1–4 and < 0.1 mg l–1 of P can be analysed at rates of 72 and 50 samples h–1, respectively. The effective detection limit of the technique was 0.01 mg l–1. Comparison of the results for DOP obtained using the proposed method were in good agreement with those obtained using standard methods. The DRP could also be determined using the same Fl manifold but without UV irradiation.

About this research paper

What this paper is about

A rapid in-line photochemical digestion for use with flow injection (Fl) to determine the dissolved organic phosphorus (DOP) in natural waters is described. The Fl system includes a simple ultraviolet (UV) photoreactor and uses the tin(II) chloride reduction of phosphomolybdate for the spectrophotometric determination of the dissolved reactive phosphorus (DRP) produced by the photo-oxidation. Samples in the range 0.1–4 and < 0.1 mg l–1 of P can be analysed at rates of 72 and 50 samples h–1, respectively. The effective detection limit of the technique was 0.01 mg l–1. Comparison of the results for DOP obtained using the proposed method were in good agreement with those obtained using standard methods. The DRP could also be determined using the same Fl manifold but without UV irradiation.

Why it matters

OpenAlex reports 65 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

A rapid in-line photochemical digestion for use with flow injection (Fl) to determine the dissolved organic phosphorus (DOP) in natural waters is described. The Fl system includes a simple ultraviolet (UV) photoreactor and uses the tin(II) chloride reduction of phosphomolybdate for the spectrophotometric determination of the dissolved reactive phosphorus (DRP) produced by the photo-oxidation. Samples in the range 0.1–4 and < 0.1 mg l–1 of P can be analysed at rates of 72 and 50 samples h–1, respectively. The effective detection limit of the technique was 0.01 mg l–1. Comparison of the results for DOP obtained using the proposed method were in good agreement with those obtained using standard methods. The DRP could also be determined using the same Fl manifold but without UV irradiation.

Key concepts: Chemistry, Detection limit, Phosphorus, Flow injection analysis, Chloride, Ultraviolet, Spectrophotometry, Chromatography

Related papers

Back to paper searchBrowse research topicsOriginal source
Spectrophotometric determination of dissolved organic phosphorus in natural waters using in-line photo-oxidation and flow injection — Research Paper | ScholarLens