2013RadioprotectionOpen access

Assessment of activity and effective dose rate of222Rn in several dwellings in Bamako, Mali

Issiaka Traoré, A. Nachab, A. Bâ, A. Nourreddine, V. Togo

Open full text 5 citations

Abstract

We used CR-39 detectors to evaluate radon activity concentrations in several habitations of Bamako. The calibration factor of the dosimeters was determined experimentally with known radon activity concentrations inside a radon chamber, and was also simulated with MCNPX. The experimental and simulated calibration factors are, respectively, kexp = 0.119 ± 0.017 and ksim = 0.126 ± 0.007 tr.cm-2.d-1.Bq-1.m3. Indoor radon activity concentrations in Bamako were found to vary from 70 ± 18 to 154 ± 35 Bq.m-3. No significant differences were observed in the mean radon activity concentrations compared with five other African countries. Taking into account an occupancy factor of 0.8 and an equilibrium factor of 0.4 for radon indoors, the effective dose rate ranges from 1.77 to 2.35 mSv.y-1. In all cases the radon activity concentrations measured were below the action limits recommended by the International Commission on Radiological Protection (ICRP) Statement on Radon.

Open-access reader

About this research paper

What this paper is about

We used CR-39 detectors to evaluate radon activity concentrations in several habitations of Bamako. The calibration factor of the dosimeters was determined experimentally with known radon activity concentrations inside a radon chamber, and was also simulated with MCNPX. The experimental and simulated calibration factors are, respectively, kexp = 0.119 ± 0.017 and ksim = 0.126 ± 0.007 tr.cm-2.d-1.Bq-1.m3. Indoor radon activity concentrations in Bamako were found to vary from 70 ± 18 to 154 ± 35 Bq.m-3. No significant differences were observed in the mean radon activity concentrations compared with five other African countries. Taking into account an occupancy factor of 0.8 and an equilibrium factor of 0.4 for radon indoors, the effective dose rate ranges from 1.77 to 2.35 mSv.y-1. In all cases the radon activity concentrations measured were below the action limits recommended by the International Commission on Radiological Protection (ICRP) Statement on Radon.

Why it matters

OpenAlex reports 5 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

We used CR-39 detectors to evaluate radon activity concentrations in several habitations of Bamako. The calibration factor of the dosimeters was determined experimentally with known radon activity concentrations inside a radon chamber, and was also simulated with MCNPX. The experimental and simulated calibration factors are, respectively, kexp = 0.119 ± 0.017 and ksim = 0.126 ± 0.007 tr.cm-2.d-1.Bq-1.m3. Indoor radon activity concentrations in Bamako were found to vary from 70 ± 18 to 154 ± 35 Bq.m-3. No significant differences were observed in the mean radon activity concentrations compared with five other African countries. Taking into account an occupancy factor of 0.8 and an equilibrium factor of 0.4 for radon indoors, the effective dose rate ranges from 1.77 to 2.35 mSv.y-1. In all cases the radon activity concentrations measured were below the action limits recommended by the International Commission on Radiological Protection (ICRP) Statement on Radon.

Key concepts: Radon, Effective dose (radiation), Dosimeter, Calibration, Environmental science, Nuclear medicine, CR-39, Radiochemistry

Related papers

Back to paper searchBrowse research topicsOriginal source
Assessment of activity and effective dose rate of222Rn in several dwellings in Bamako, Mali — Research Paper | ScholarLens