1990•PubMedRequires access

Technetium-99m-human polyclonal IgG radiolabeled via the hydrazino nicotinamide derivative for imaging focal sites of infection in rats.

Matthew J. Abrams, Malik Eid Juweid, C I tenKate, David Asa Schwartz, Marguerite M. Hauser, Forrest E. Gaul, Anthony J. Fuccello, R H Rubin, H. William Strausś, Alan J. Fischman

Open publisher page 361 citations

Abstract

The biologic behavior of human polyclonal immunoglobulin (IgG) radiolabeled with technetium-99m (99mTc) by a novel method, via a nicotinyl hydrazine derivative, was evaluated in rats. Technetium-99m- and indium-111-IgG were co-administered to normal rats and biodistribution was determined at 2, 6, and 16 hr. The inflammation imaging properties of the two reagents were compared in rats with deep-thigh infection due to Escherichia coli. Blood clearance of both antibody preparations was well described by a bi-exponential function: (99mTc-IgG: t1/2 = 3.82 +/- 0.89 and 57.52 +/- 1.70 hr. 111In-IgG: 3.93 +/- 0.117 and 40.71 +/- 1.26 hr). Biodistributions in the solid organs were similar, however, small but statistically significant differences were detected: 99mTc-IgG greater than 111In-IgG in lung, liver, and spleen; 99mTc-IgG less than 111In-IgG in kidney and skeletal muscle (p less than 0.01). At all three imaging times, target-to-background ratio and percent residual activity for the two compounds were remarkably similar. These studies establish that human polyclonal IgG labeled with 99mTc via a nicotinyl hydrazine modified intermediate is equivalent to 111In-IgG for imaging focal sites of infection in experimental animals.

About this research paper

What this paper is about

The biologic behavior of human polyclonal immunoglobulin (IgG) radiolabeled with technetium-99m (99mTc) by a novel method, via a nicotinyl hydrazine derivative, was evaluated in rats. Technetium-99m- and indium-111-IgG were co-administered to normal rats and biodistribution was determined at 2, 6, and 16 hr. The inflammation imaging properties of the two reagents were compared in rats with deep-thigh infection due to Escherichia coli. Blood clearance of both antibody preparations was well described by a bi-exponential function: (99mTc-IgG: t1/2 = 3.82 +/- 0.89 and 57.52 +/- 1.70 hr. 111In-IgG: 3.93 +/- 0.117 and 40.71 +/- 1.26 hr). Biodistributions in the solid organs were similar, however, small but statistically significant differences were detected: 99mTc-IgG greater than 111In-IgG in lung, liver, and spleen; 99mTc-IgG less than 111In-IgG in kidney and skeletal muscle (p less than 0.01). At all three imaging times, target-to-background ratio and percent residual activity for the two compounds were remarkably similar. These studies establish that human polyclonal IgG labeled with 99mTc via a nicotinyl hydrazine modified intermediate is equivalent to 111In-IgG for imaging focal sites of infection in experimental animals.

Why it matters

OpenAlex reports 361 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

The biologic behavior of human polyclonal immunoglobulin (IgG) radiolabeled with technetium-99m (99mTc) by a novel method, via a nicotinyl hydrazine derivative, was evaluated in rats. Technetium-99m- and indium-111-IgG were co-administered to normal rats and biodistribution was determined at 2, 6, and 16 hr. The inflammation imaging properties of the two reagents were compared in rats with deep-thigh infection due to Escherichia coli. Blood clearance of both antibody preparations was well described by a bi-exponential function: (99mTc-IgG: t1/2 = 3.82 +/- 0.89 and 57.52 +/- 1.70 hr. 111In-IgG: 3.93 +/- 0.117 and 40.71 +/- 1.26 hr). Biodistributions in the solid organs were similar, however, small but statistically significant differences were detected: 99mTc-IgG greater than 111In-IgG in lung, liver, and spleen; 99mTc-IgG less than 111In-IgG in kidney and skeletal muscle (p less than 0.01). At all three imaging times, target-to-background ratio and percent residual activity for the two compounds were remarkably similar. These studies establish that human polyclonal IgG labeled with 99mTc via a nicotinyl hydrazine modified intermediate is equivalent to 111In-IgG for imaging focal sites of infection in experimental animals.

Key concepts: Polyclonal antibodies, Immunoglobulin G, Spleen, Biodistribution, Antibody, Chemistry, Technetium-99m, Immunoglobulin M

Related papers

Back to paper searchBrowse research topicsOriginal source
Technetium-99m-human polyclonal IgG radiolabeled via the hydrazino nicotinamide derivative for imaging focal sites of infection in rats. — Research Paper | ScholarLens