1997Journal of Analytical ToxicologyRequires access

Simultaneous Determination of Heroin, 6-Monoacetylmorphine, Morphine, and its Glucuronides by Liquid Chromatography-Atmospheric Pressure Ionspray-Mass Spectrometry

P. Zuccaro, R. Ricciarello, Simona Pichini, Roberta Pacifici, Ilaria Altieri, Manuela Pellegrini, G. D’Ascenzo

Open publisher page 80 citations

Abstract

A new analytical technique has been developed for the simultaneous determination of heroin, 6-monoacetylmorphine, morphine, morphine-6- and 3-glucuronides, and codeine in serum using liquid chromatography coupled with ionspray mass spectrometry. The analytes and the internal standard, nalorphine, were subjected to solid-phase extraction (SPE) using ethyl SPE columns before chromatography. The chromatographic separation of the analytes was achieved using a normal phase column and a water-methanol-acetonitrile-formic acid mobile phase at a flow rate of 230 microL/min. The mass spectrometer was operated in selected-ion monitoring mode. Under these conditions, the limit of quantitation was 0.5 ng/ml for heroin, 4 ng/ml for 6-monoacetylmorphine, 4 ng/ml for morphine, 1 ng/ml for morphine-3-glucuronide, 4 ng/ml for morphine-6-glucuronide, and 4 ng/mL for codeine. Serum levels of heroin metabolites were determined in C57BL/6 inbred mice after a dose of 20 mg/kg heroin administered subcutaneously. 6-monoacetylmorphine showed a peak concentration of 0.93 micrograms/mL serum at 3 min, whereas morphine and morphine-3-glucuronide achieved their peak concentrations of 9.6 and 2.9 micrograms/mL serum at 10 and 20 min, respectively. Finally, the absence of morphine-6-glucuronide and codeine excluded the possibility of their formation from morphine in this animal model.

About this research paper

What this paper is about

A new analytical technique has been developed for the simultaneous determination of heroin, 6-monoacetylmorphine, morphine, morphine-6- and 3-glucuronides, and codeine in serum using liquid chromatography coupled with ionspray mass spectrometry. The analytes and the internal standard, nalorphine, were subjected to solid-phase extraction (SPE) using ethyl SPE columns before chromatography. The chromatographic separation of the analytes was achieved using a normal phase column and a water-methanol-acetonitrile-formic acid mobile phase at a flow rate of 230 microL/min. The mass spectrometer was operated in selected-ion monitoring mode. Under these conditions, the limit of quantitation was 0.5 ng/ml for heroin, 4 ng/ml for 6-monoacetylmorphine, 4 ng/ml for morphine, 1 ng/ml for morphine-3-glucuronide, 4 ng/ml for morphine-6-glucuronide, and 4 ng/mL for codeine. Serum levels of heroin metabolites were determined in C57BL/6 inbred mice after a dose of 20 mg/kg heroin administered subcutaneously. 6-monoacetylmorphine showed a peak concentration of 0.93 micrograms/mL serum at 3 min, whereas morphine and morphine-3-glucuronide achieved their peak concentrations of 9.6 and 2.9 micrograms/mL serum at 10 and 20 min, respectively. Finally, the absence of morphine-6-glucuronide and codeine excluded the possibility of their formation from morphine in this animal model.

Why it matters

OpenAlex reports 80 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

A new analytical technique has been developed for the simultaneous determination of heroin, 6-monoacetylmorphine, morphine, morphine-6- and 3-glucuronides, and codeine in serum using liquid chromatography coupled with ionspray mass spectrometry. The analytes and the internal standard, nalorphine, were subjected to solid-phase extraction (SPE) using ethyl SPE columns before chromatography. The chromatographic separation of the analytes was achieved using a normal phase column and a water-methanol-acetonitrile-formic acid mobile phase at a flow rate of 230 microL/min. The mass spectrometer was operated in selected-ion monitoring mode. Under these conditions, the limit of quantitation was 0.5 ng/ml for heroin, 4 ng/ml for 6-monoacetylmorphine, 4 ng/ml for morphine, 1 ng/ml for morphine-3-glucuronide, 4 ng/ml for morphine-6-glucuronide, and 4 ng/mL for codeine. Serum levels of heroin metabolites were determined in C57BL/6 inbred mice after a dose of 20 mg/kg heroin administered subcutaneously. 6-monoacetylmorphine showed a peak concentration of 0.93 micrograms/mL serum at 3 min, whereas morphine and morphine-3-glucuronide achieved their peak concentrations of 9.6 and 2.9 micrograms/mL serum at 10 and 20 min, respectively. Finally, the absence of morphine-6-glucuronide and codeine excluded the possibility of their formation from morphine in this animal model.

Key concepts: Chromatography, Chemistry, Codeine, Morphine, Detection limit, Solid phase extraction, Glucuronide, Mass spectrometry

Related papers

Back to paper searchBrowse research topicsOriginal source
Simultaneous Determination of Heroin, 6-Monoacetylmorphine, Morphine, and its Glucuronides by Liquid Chromatography-Atmospheric Pressure Ionspray-Mass Spectrometry — Research Paper | ScholarLens